Opticon assumes no liability for any direct, indirect, consequential or incidental damages arising out of use or inability to use both the hardware and software, even if Opticon has been informed about the possibility of such damages.
Opticon Specifications Manual 1. Abstract This manual provides specifications for the C37 barcode scanner. 2. Overview The C37 is a handheld CCD barcode scanner. A new scanning algorithm and 2500 pixels-CCD linear image sensor provide smooth scanning performance. The C37 can be configured to scan both positive and negative barcodes. Scanned data is transferred via an RS-232C, USB, or Wedge interface.
Opticon Specifications Manual 3. Physical Features 3.1. Dimensions W 74.5 × D 149.5 H 52.5 mm 3.2. Weight 85 grams ± 5 grams (excluding cable weight) 4. Environmental Specifications 4.1. Operating Temperature and Humidity Temperature: 0° to +50° C Humidity: 5 to 95% RH 4.2.
Opticon Specifications Manual 5.2. Electrical Characteristics RS232 5.2.1. Parameter Symbol Unit Operating voltage Operating current 1: — LED: ON, Buzzer: OFF Operating current 2: — LED: ON, Buzzer/LED: OFF Rush current peak — PEAK Stand-by current 1: — Auto-trigger OFF Stand-by current 2: —...
Opticon Specifications Manual Output Specifications 5.3.2. Parameter Value Output voltage 6.0 V ±5% Power ripple 120 m Vp-p max. (rated load) Maximum current Short-circuit protection Available Conditions • Connect 1Ω resistance to a power supply line in series and measure the current by the voltage between both ends of resistance.
Opticon Specifications Manual 7. Technical Specifications The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions Ambient temperature Room temperature (5 to 35º C) and humidity: Room humidity (45% to 85% RH) Ambient light: 500 to 1000 lx...
Opticon Specifications Manual Depth of Field 7.3.2. 0 to15 mm The depth of field is measured from the edge of the scanner. Figure 3: Depth of field Conditions Barcode Sample: OPTOELECTRONICS Test Sample N/W Ratio: 1:2.5 Angle: α = 0°, β = 0°, γ = 0°...
Opticon Specifications Manual Skew Angle and Dead Zone 7.4.2. Scanning performance is guaranteed when skew angle: β ≤ ±70° (Excluding dead zone) Dead zone: β = ±20° (There are some areas in which decoding fails due to specular reflection) 2 = 0°...
Opticon Specifications Manual 7.5. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R = 15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R = 20 mm. Figure 7: Curvature Conditions Barcode Sample: OPTOELECTRONICS Test Sample Angle: Pitch angle: γ...
Opticon Specifications Manual Signal Level 8.1.2. Signal Name RS-232C Level (V) Mark/OFF Space/ON -5 to -15 +5 to +15 -3 to -15 +3 to +15 -5 to -15 +5 to +15 -3 to -15 +3 to +15 Pin Assignment 8.1.3.
Opticon Specifications Manual Interface Circuit 8.1.4. DC J Figure 8: Interface circuit Character Format 8.1.5. Uses the same format for both sending and receiving. Figure 9:Character format (same for both sending and receiving) Communication Format 8.1.6. Figure 10: Communication format...
Opticon Specifications Manual Handshaking 8.1.7. Select handshaking options using the menu or command listed below. Handshaking Menu/Command No handshake BUSY/READY MODEM ACK/NAK ACK/NAK NO RESPONSE a) No Handshaking The scanner attempts the communication regardless of the state of the host computer.
Opticon Specifications Manual ACK/NAK timeout can be set as follows using the menu or commands. ACK/NAK timeout Menu / Command Indefinitely (default) 100 ms 500 ms 1000 ms Figure 13: ACK/NAK...
Opticon Specifications Manual d) ACK/NAK NO RESPONSE When no response from the host is received within the setting time, the scanner assumes an ACK response, and returns to the initial state without the error buzzer. The other actions are the same as ACK/NAK.
Opticon Specifications Manual 8.2. USB-HID and USB-VCP Interface Specifications Settings 8.2.1. Reading the menu barcodes in section 10.1 can set the USB interface default. The interface is full-speed USB (12 Mbps). Note: You must install the USB-VCP driver on the host.
Opticon Specifications Manual Connectors 9.3.1. a) DOS/V Host Connector Figure 20: DOS/V host connector Contact Number Signal Name CPU_DATA CPU_CLK b) DOS/V Keyboard Connector Figure 21: DOS/V keyboard connector Contact Number Signal Name KEY_DATA KEY_CLK Do not use the keyboard while the scanner is transmitting the data to the host.
Opticon Specifications Manual Notes: In the “Reading” column, “ ” means “Enable reading” and “X” means “Disable reading.” In the “Transmit code length” column, “ ” means “Transmit code length” and “X” means “Do not transmit code length.” In the “Transmit CD” column, “ ” means “Transmit check digit”...
Opticon Specifications Manual 11. Serial Number The serial number shown below is affixed to the scanner. クラス1LED製品 JIS C6802:2005 O P R 4101 OPTO ELECTRONICS CO.,LTD. WARABI-SHI,SAITAMA MADE IN CHINA Figure 22: Serial number diagram 12. Packaging Specifications 12.1. Individual Packaging Specification Put the scanner in a protective foam bag and place it in a single packing box.
Opticon Specifications Manual 13.3. Shock Drop Test (without packaging) 13.3.1. No malfunction occurred after the following drop test. Drop Test: Drop the scanner from a height of 150 cm onto a concrete floor three times on each of 5 sides.
Opticon Specifications Manual Cable Strength 13.5.1. No malfunction occurred after the following pulling test. Pulling test: Fix the scanner and pull the cable with the force of 2.5 kg (24.5N) for 1 second. Repeat 20 times. Cable Tail Bending Test 13.5.2.
Opticon Specifications Manual 15. Trigger and Read Options The product has an optional auto trigger setting, which starts barcode reading automatically by using sensor detection. The scanner starts barcode reading after detecting reflection from the surface when the auto trigger is used.
Opticon Specifications Manual 17. Regulatory Compliance 17.1. LED Safety The scanner emits light beams. JIS C6802: 2005: Class 1 IEC 825-1/EN 60825-1: Class 1 17.2. EMC EN55022 EN55024 VCCI Class B: This is a Class B product, to be used in a domestic environment based on the Technical Requirement of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI).
The scanner may be damaged by voltage drops. 18.5. AC/DC Adapter Opticon shall not be held responsible for any damages caused by using an AC adapter not provided by Opticon. Use only the supplied AC adapter with the enclosed region specific plugs for connection to the wall socket.
Opticon Specifications Manual 19. Mechanical Drawing Dimensions: 149.5 mm x 74.5 mm x 52.5 mm (except protruding parts) Figure 25: Mechanical drawing Scanner...