Page 3
This manual may not, in whole or in part, be Serial number copied, photocopied, reproduced, translated or A serial number appears on all Opticon converted to any electronic or machine products. This official registration number is readable form without prior written consent of strictly related to the device purchased.
OPTICON Universal menu book TABLE OF CONTENTS Code options (continued) Introduction ..........U1 3.3.19. Options for Codablock F .....U76 3.3.20. Options for DataMatrix......U76 Defaults ............U5 3.3.21. Options for Aztec ........U77 3.3.21. Options for Chinese Sensible code ..U78 Interface ...........U7 3.3.22. Options for QR Code ......U79 3.3.23.
Page 5
Fig. 3.15. Options for UPC-E, +2, +5 ....U48 Fig. 4.03. Set prefix and suffix ......U85 Fig. 3.16. Options for EAN-13.......U50 Fig. 4.04. OPTICON Code identifiers ...U86 Fig. 3.17. Options for EAN-13, +2, +5...U50 Fig. 4.05. AIM/ISO15424 Code identifiers ..U87 Fig. 3.18. Options for EAN-8......U50 Fig.
OPTICON Universal menu book INTRODUCTION This menu book is intended for setting up your bar code reader to optimize its performance for your particular application. When the required options have been configured, they remain in the reader, even after power down. The reader can be returned to factory default by reading the default label.
OPTICON Universal menu book • 5: Configuring via the menu book Use chapter 5 to select the read options to your To configure the required options proceed as preference. These options affect the read follows: mode, read time, trigger and redundancy.
1B 4D 34 31 4B ØD readers which can be configured with this Each 3-character command should be Universal menu book. In addition OptiConfigure preceded with the '[' character (Hex 5B) i.e. offers product specific and less often used <Esc>[BCC<CR> is used to enable Data menu labels.
OPTICON Universal menu book 1. DEFAULTS This option allows you to undo all previously configured options and bring the reader's configuration back to factory default settings. These factory default settings are printed in bold. Note that differences may occur depending on the type of interface as will be mentioned in the text.
Page 13
OPTICON Universal menu book 1. Defaults _ZZ_ _U2_ RS232 _SS_ Serial TTL _UB_ AT wedge _SU_ USB-HID _C01_ USB-VCP _SO_ Bluetooth-SPP _C02_ Bluetoooth-HID IEEE 802.15.4-HID _SM_ IEEE 802.15.4-VCP _ZZ_...
OPTICON Universal menu book 2. INTERFACE This chapter describes the configurable transmission options for your reader. Some options may not be relevant to the type of reader you have. An attempt to configure the reader for such options does not affect its...
OPTICON Universal menu book 2.1. RS232 options This paragraph describes the specific options TxD: for a reader with an RS232 interface. Transmitted Data: Transmits data from the reader to the host. This connection is Bar code readers with an RS232 interface are mandatory.
OPTICON Universal menu book 2.1.1. Baud rate settings The baud rate is the rate at which bits are transmitted from the reader to the host, and vice versa. Both the reader and the host should be set to the same baud rate...
OPTICON Universal menu book 2.1.2. Data, parity and stop bits The data characters may be transferred in one Fig. 2.03. Data, parity, stop bits of the following formats: START 7 Bit Data STOP A parity bit may be added to every character so...
OPTICON Universal menu book 2.1.3. Handshaking Data flow control is available using either ON the reader is allowed to transmit data. hardware (Modem, Busy/Ready) or software When all data has been transmitted, the reader (XON/XOFF). In addition, an optional will turn RTS OFF. In response, the host should acknowledgement control is available (ACK/ turn OFF the reader's CTS.
OPTICON Universal menu book Response: "None" 6. ACK/NAK no response: Action: If there is no response within one The difference from the ACK/NAK mode is that second then the reader terminates when no response from the host is received transmission with an error buzzer. See figure within 100 ms, the reader assumes that the 2.06.
Page 20
OPTICON Universal menu book 2.1.3. Handshaking _ZZ_ _P0_ No handshake _P1_ Busy/ready _P2_ Modem _ZG_ XON/XOFF _P3_ ACK/NAK _P4_ ACK/NAK NO RESPONSE _I0_ Flow Control time out indefinitely _I1_ Flow Control time out 100ms _I2_ Flow Control time out 200ms...
OPTICON Universal menu book 2.1.4. Intercharacter delay for RS232 The intercharacter delay introduces a configurable time delay after each character transmitted. This may be used if the connected computer or terminal does not support flow control and is not capable of handling the received data.
OPTICON Universal menu book 2.2. Keyboard wedge/USB options This paragraph describes the options which are With keyboard: relevant to readers with a wedge or USB Use this mode in case a keyboard is connected interface. The following parameters can be to the PC wedge Y-cable.
Page 23
OPTICON Universal menu book 2.2.1. Keyboard language Keyboards are also different depending on country or language. Examples are the QWERTY and AZERTY keyboards. Select the same language that has been selected on your The languages supported depend on the reader model and software release. Please consult your sales office for the languages currently supported.
Page 24
OPTICON Universal menu book _ZZ_ _PK_ Swiss ( German ) _PI_ Dutch _PJ_ Belgian _PD_ Swedish _PG_ Finnish _KK_ Danish _PE_ Norwegian _PM_ Japanese _WF_ Czech _ZZ_...
OPTICON Universal menu book 2.2.2. Special options Auto NumLock mode: When selecting this option, the bar code reader This section contains some specialised automatically uses the correct NumLock state. keyboard options. No CAPSLOCK mode: Do not use numpad: This options cancels the CAPSLOCK mode.
OPTICON Universal menu book The intercharacter delay can be used to adapt 2.2.3. Intercharacter delay for wedges/USB the reader's data transmission speed to the system. If the transmission speed is too high, the system may not be able to receive all characters.
Bluetooth dongle connection: This section is intended to configure a wireless In case a third party Bluetooth dongle is used, connection to an Opticon cradle and third party the Bluetooth address, pin code and security dongles. Options are available to minimize the options needs to be configured manually.
Bluetooth Address: 00 04 12 34 AF 56 number with 6 hex digit pairs. Secure Connection: Not Required. To configure an Opticon Bluetooth bar code Example Step 2. reader to connect to a third party Bluetooth • read the following codes: dongle, the following steps must be taken: <SET>...
Page 29
OPTICON Universal menu book 2.3.1. Bluetooth address _ZZ_ _BDAS_ Set bluetooth address BDAS label _BDAE_ End bluetooth address BDAE label _DIAU_ DIAU Disable auto connect _ENAU_ ENAU Enable auto connect _CNPC_ CNPC Connect to PC _CNCR_ CNCR Connect to Cradle...
OPTICON Universal menu book 2.3.2. Bluetooth security To provide additional security connections, the Use 'secured' connections Bluetooth specification allows you to enable a If you want to use 'secured' connections: special security setting, so that a PIN-code is • scan enable authentication label required from the bar code reader in order to •...
OPTICON Universal menu book 2.3.3. Trigger connection options Press trigger switch time to connect: Discoverable and connectable: This is the time the trigger switch needs to be When the trigger switch is pressed for the pressed where after the reader tries to configured amount of time, the reader can establish a connection.
Page 32
OPTICON Universal menu book _ZZ_ _BBC_ Trigger to connect Trigger to make _BBD_ connectable and discoverable _ZZ_...
OPTICON Universal menu book 2.3.4. Trigger disconnect options Press trigger switch time to disconnect: This is the time the trigger switch needs to be pressed where after the reader disconnects. _ZZ_ _PD00_ PD00 Disabled _PD01_ PD01 1 second _PD02_ PD02...
OPTICON Universal menu book 2.3.5. Auto disconnect options Auto disconnect: If the reader is idle for the configured time, it will disconnect. Purpose options are power saving. _ZZ_ _AD00_ AD00 Disabled _AD01_ AD01 10 minutes _AD02_ AD02 20 minutes _AD03_...
OPTICON Universal menu book 2.3.6. Auto reconnect options time is expired, the reader stops trying. The Auto reconnect: If the reader is disconnected because it is out reader will not reconnect after reading the manually disconnect label or after auto...
OPTICON Universal menu book 2.3.7. Wireless power saving IEEE 802.15.4 power saving: Activation levels: IEEE 802.15.4 based readers change the In order to reduce the power consumption it is antenna output power instead of changing the possible to set the activity rate of the reader.
OPTICON Universal menu book 2.3.8. Memorizing Memorizing options can be used to temporary Clear all memorized data: store bar code data in case the bar code reader All memorizing data is deleted and the storage lost its connection. As soon the reader is area is cleared.
Page 38
OPTICON Universal menu book 2.3.8. Memorizing _ZZ_ _D D TMD_ Data memorizing DTMD disabled _DTME_ Data memorizing DTME enabled _BM0_ Memorize after connection loss _BM1_ Always memorize when not connected _BM2_ Memorize always (Batch mode) _ZZ_ 2.3.8. Memorizing commands _+-MCLR-+_...
OPTICON Universal menu book Note: 3. CODE OPTIONS The menubook categorizes the barcodes as The menu options in this chapter are intended groups of different symbologies with their to adjust the decoding settings of the reader: translations and sometimes with relations to •...
OPTICON Universal menu book 3.1. Setting of readable codes These options do not affect the reading of the Example 2: If you want to read one of the special bar codes menu labels. The required bar code types can be selected by enabling a single readable code that is a variation of the readable code, read only and enabling readable codes.
Page 42
OPTICON Universal menu book 3.1.1. Enabling a single read. code _ZZ_ _A0_ All codes excl. add-on _J0_ Only all UPC and EAN codes _J1_ UPC only _J2_ UPC + 2 only _J3_ UPC + 5 only _J4_ EAN only _J5_...
OPTICON Universal menu book _ZZ_ _RA_ S-Code only _AB_ Matrix 2of5 only _JE_ Chinese Post Matrix 2of5 only _JL_ Korean Postal Authority code only _D5H_ Intelligent Mail Barcode only _D6C_ POSTNET only _A4_ IATA only _A7_ MSI/Plessey only _A9_ Telepen only...
OPTICON Universal menu book _ZZ_ _J9_ GS1 DataBar only _JJ_ GS1 DataBar Limited only _JK_ GS1 DataBar Expanded only _D4R_ Codablock F only _BG2_ DataMatrix ECC000 - 140 only _BC0_ DataMatrix ECC200 only _BC5_ Aztec only _BF4_ Aztec runes only...
OPTICON Universal menu book _ZZ_ _BC4_ MicroPDF417 only _BCA_ Enable all 1D codes only _BCB_ Enable all 2D codes only _ZZ_ 3.1.2. Enabling of readable codes With this option you can set the reader to read a number of bar code types or simply enable additional bar code types.
OPTICON Universal menu book _ZZ_ _BCM_ Enable all 1D codes _BCN_ Enable all 2D codes _B0_ Disable all _ZZ_ 3.2. Setting of number of characters If you are going to read bar codes of known Fixed length ON all codes.
OPTICON Universal menu book It is possible to configure a fixed length or a Fixed length ON for selected codes: minimum and a maximum length for selected This option enables fixed length checking for symbologies by reading the respective option...
OPTICON Universal menu book Minimum length for selected codes: Maximum length for selected codes: This option modifies the default minimum This option enables the maximum length length table. The number of minimum lengths checking. The number of maximum lengths which can be configured is reader dependent.
Page 52
OPTICON Universal menu book Serial programming: To set a length using serial commands, the sequence is as follows: <ESC> <command> <SPACE>*<CodeID>* <Length 1> <Length 2**> <CR> *(if required by <command>) **(length 2 may be the same length as length 1,...
OPTICON Universal menu book 3.3. Setting code specific options Code specific options may be configured Not transmit CD: This option disables the transmission of the affecting: check digit. If the check digit calculation is • enabling and disabling code variants and...
OPTICON Universal menu book 3.3.1. Options for UPC-A The UPC-A symbology is a fixed length Fig. 3.12. Options for UPC-A symbology encoding 11 data digits, a check digit and non printable start/stop characters. UPC-A The following characters are supported: leading...
OPTICON Universal menu book 3.3.2. Options for UPC-E The UPC-E symbology is a fixed length symbology encoding 6 data digits, a check digit Fig. 3.14. Options for UPC-E and non printable start/stop characters. The following characters are supported: UPC-E • the digits 0 upto 9...
Page 56
OPTICON Universal menu book 3.3.2. Options for UPC-E _ZZ_ _E7_ UPC-E, No leading digit, transmit CD _E9_ UPC-E, No leading digit, not transmit CD _E6_ UPC-E, Leading digit, transmit CD _E8_ UPC-E, Leading digit, not transmit CD _6Q_ Transmit UPC-E as is...
OPTICON Universal menu book 3.3.3. Options for EAN-13 and EAN-8 EAN-13: The EAN-13 symbology is a fixed length Fig. 3.16. Options for EAN-13 and EAN-8 symbology encoding 12 data digits, a check digit and non printable start/stop characters. EAN-13 The following characters are supported:...
Page 58
OPTICON Universal menu book 3.3.3. Options for EAN-13 and EAN-8 _ZZ_ _6J_ EAN-13 not transmit CD _6K_ EAN-13 transmit CD _6H_ EAN-8 not transmit CD _6I_ EAN-8 transmit CD _IB_ Disable ISBN translation _IA_ Enable ISBN translation _IK_ Enable ISBN if possible...
OPTICON Universal menu book 3.3.4. Options for Code 39 and It. Pharm. Code 39: Italian Pharmaceutical only: Code 39 is a variable length symbology with an In this mode the decoded data characters are optional check digit and printable start/stop translated to the Italian Pharmaceutical format.
Page 60
OPTICON Universal menu book Fig. 3.21. Options for Code 39 and It.Pharm. Fig. 3.20. Options for Code 39 and It.Pharm. Italian Pharmaceutical Code 39 data start leading check stop start data check stop (8 digits) char. digit char. char. (0 or more char.) digit char.
Page 61
OPTICON Universal menu book _ZZ_ _D8_ Not transmit CD _D9_ Transmit CD _D1_ Not transmit ST/SP _D0_ Transmit ST/SP _DA_ Not transm. ld. A for It. Pharm.Code _DB_ Transmit leading A for It. Pharm.Code _8D_ Minimum 3 digits _8E_ Minimum 1 digit...
OPTICON Universal menu book 3.3.5. Options for Codabar Codabar (NW7): Codabar (NW7) is a variable length symbology Fig. 3.23. Options for Codabar with an optional check digit and printable start/ stop characters. The next characters are Codabar supported: start data...
OPTICON Universal menu book Space insertion: This option inserts spaces in position 2, 7, 13, Fig. 3.26. Options for Codabar of the data string for use in library systems. Codabar Start and Stop ST/SP translation: This option enables the translation and Not transmit ST/SP transmission of the start and stop characters.
OPTICON Universal menu book 3.3.5. Options for Codabar _ZZ_ _HA_ Enable only Codabar normal mode _H4_ Enable only ABC code _H5_ Enable only CX code _H3_ Enable Codabar, ABC and CX _H7_ Not check CD _H6_ Check CD _H9_ Not transmit CD...
Page 65
OPTICON Universal menu book _ZZ_ _F1_ ST/SP: ABCD/TN*E _F2_ ST/SP: abcd/tn*e ST/SP: _HJ_ <DC1><DC2><DC3><DC4>/ <DC1><DC2><DC3><DC4> _HC_ Minimum data one character _HB_ Minimum data three characters _HF_ Minimum data five characters _HI_ Disable intercharacter gap check _HH_ Enable intercharacter gap check...
OPTICON Universal menu book 3.3.6. Options for 2of5 and S-Code Code 2of5: Options for code 2of5: Code 2of5 is a variable length symbology with • disable transmission of the check digit an optional check digit and non printable start • enable check digit check and stop characters.
OPTICON Universal menu book 3.3.6. Options for 2of5 and S-Code _ZZ_ _E1_ Not transmit CD _E0_ Transmit CD _G0_ Not check CD _G1_ Check CD _GE_ Minimum data one character _GF_ Minimum data three character _GI_ Minimum data five character...
OPTICON Universal menu book 3.3.7. Options for IATA Check digit calculation: The IATA code is a variable length symbology If the check digit calculation is required, then with an optional check digit and non printable the appropriate calculation method must be start/stop characters.
OPTICON Universal menu book 3.3.8. Options for MSI/Plessey MSI Plessey is a variable length symbology with one or two optional check digit calculations CD1 and CD2 and non printable start/stop Fig. 3.29. Options for MSI/Plessey characters. The following characters are...
Page 70
OPTICON Universal menu book 3.3.8. Options for MSI/Plessey _ZZ_ _4A_ Not check CD _4B_ Check 1 CD = MOD 10 _4C_ Check 2 CD's = MOD 10/ MOD 10 _4D_ Check 2 CD's = MOD 10/ MOD 11 _4R_ Check 2 CD's = MOD 11/...
OPTICON Universal menu book 3.3.9. Options for Telepen Telepen is a variable length symbology with a check digit and non printable start/stop Fig. 3.30. Options for Telepen characters. The following characters are supported: Telepen • in numeric mode, the digits 00 upto 99 •...
OPTICON Universal menu book 3.3.10. Options for UK/Plessey Space insertion: UK Plessey is a variable length symbology with This option inserts spaces in position 2, 5, 11, a mandatory checksum and non printable start/ 14 of the data string for use in library systems.
OPTICON Universal menu book 3.3.11. Options for Code 128 and GS1-128 Code 128: FNC2 Concatenation: Code 128 is a variable length symbology with a If a Code 128 bar code contains a leading mandatory check digit and non printable start/ FNC2 character, the data is stored into the stop characters.
Page 74
OPTICON Universal menu book 3.3.11. Options for Code 128 and GS1-128 _ZZ_ _OF_ Disable GS1-128 _JF_ Enable GS1-128 only _OG_ Enable GS1-128 if possible _MP_ Disable concatenation _MO_ Enable concatenation _ZZ_...
OPTICON Universal menu book 3.3.12. Options for Code 93 Code 93 is a variable length symbology with 2 mandatory check digits and non printable start/ Fig. 3.34. Options for Code 93 stop characters. The following characters are supported: Code 93 •...
Page 76
OPTICON Universal menu book 3.3.12. Options for Code 93 _ZZ_ _9Q_ Not check CD _AC_ Check CD _DZ_ Not transmit CD _DY_ Transmit CD _+W_ Disable concatenation _+V_ Enable concatenation _ZZ_...
OPTICON Universal menu book 3.3.13. Options for Code 11 Options for Code 11: Code 11 is a variable length symbology with 1 • disable check digit(s) or 2 optional check digits and non printable • automatic checking for 1 or 2 check digits start/stop characters.
OPTICON Universal menu book 3.3.14. Options for Korean Postal Authority code Transmit dash: Korean Postal Authority code is a fixed length The dash character '-' ( hex 2D ) is printed numeric symbology with a mandatory check between the 3rd and 4th digit digit.
OPTICON Universal menu book 3.3.15. Options for Intelligent Mail Barcode 3.3.16. Options for POSTNET Intelligent Mail Barcode is a symbology in four POSTNET (Postal Numeric Encoding different states. It is formerly known as Technique) is a height modulated symbology OneCode and is a variant of the 4-State with a number of fixed lengths.
OPTICON Universal menu book 3.3.17. Options for GS1 Databar The next GS1 Databar versions are supported. • Omnidirectional/Truncated/Stacked (refer to GS1 Databar) GS1 Databar is formerly known as RSS familiy • Limited (refer to GS1 Databar Limited) including the RSS-14 group. Support for GS1 •...
OPTICON Universal menu book 3.3.18. Options for Composite Codes CC-A is a modified MicroPDF417 version. CC-B is standard MicroPDF417. Fig. 3.41. Options for Composite Codes CC-C is standard PDF417. Composite A Maximum data capacity: • CC-A: 56 characters 1D data...
Page 82
OPTICON Universal menu book 3.3.18. Options for Composite Codes _ZZ_ _RQ_ Not ignore composite link flag _RP_ Ignore composite link flag _BHF_ Disable Composite on GS1-Databar _BHE_ Enable Composite on GS1-Databar As a single component, _BL0_ only 1D component is...
OPTICON Universal menu book 3.3.19. Options for Codablock F 3.3.20. Options for DataMatrix Codablock-F is variable size multi row (stacked) Data Matrix is a variable size matrix symbology symbology based on Code 128. All features of with selectable error correction levels.
OPTICON Universal menu book 3.3.21. Options for Aztec Aztec code is a variable size matrix symbology Options for DataMatrix: with selectable error correction levels. • Structured append time out: see chapter Read options Maximum data capacity: Standard Aztec: • alphanumeric: 3067 characters Fig.
OPTICON Universal menu book 3.3.22. Options for Chinese Sensible code Chinese Sensible code is a matrix symbology Encodable characters: with selectable error correction levels. The • numerical values 0-9 code allows 84 variable sized versions. • ASCII value 0 - 127 ( ISO 646 ) •...
OPTICON Universal menu book 3.3.23. Options for QR Code Options for QR code: QR code is a variable size matrix symbology • structured append time out: see read mode with selectable error correction levels. options • no further options supported...
OPTICON Universal menu book 3.3.24. Options for Micro QR Code 3.3.25. Options for Maxicode Micro QR code is a compact version for the Maxicode is a fixed size matrix symbology with regular QR Code. selectable error correction levels. Maximum data capacity:...
OPTICON Universal menu book 3.3.26. Options for PDF417 3.3.27. Options for MicroPDF417 PDF417 is variable size multi row (stacked) MicroPDF417 is variable size multi row symbology with selectable error correction (stacked) symbology with fixed error correction levels. levels. Maximum data capacity: Maximum data capacity: •...
OPTICON Universal menu book 4. STRING OPTIONS This chapter describes the alterations which can be made to the format of the transmitted data string. Options available are: Case conversion • conversion of bar code data The bar code data has the format as described in chapter ‘Code Options’.
OPTICON Universal menu book 4.1. Case conversion The bar code data may be converted to either lower or upper case or the case may be Fig. 4.02. Case conversion exchanged. These options may be used if the user of a wedge has a preference to leave for...
OPTICON Universal menu book 4.2. Set prefix and suffix If the direct input keyboard key <return> from A prefix and suffix of maximum 4 direct input this chapter is selected then the result is a entries each may be included in front and at the <carriage return>...
OPTICON Universal menu book In case the modifier is an asterix (*), the value Fig. 4.04. Set prefix and suffix depends on the options of the symbology or on OPTICON Code identifiers the configured Code options. For details refer to their own respective modifier tables.
OPTICON Universal menu book Fig. 4.05. Set prefix and suffix Fig. 4.06. Modifiers for Code 39 AIM/ISO15424 Code identifiers for : AIM/ISO15424 Code identifiers ]AIM-ID Code options ]AIM-ID Symbology *(Modifier table) Normal Code 39 (D5) UPC-A Not check CD (C1)
OPTICON Universal menu book Fig. 4.07. Modifiers for Codabar Fig. 4.09. Modifiers for IATA AIM/ISO15424 Code identifiers for : AIM/ISO15424 Code identifiers for : Code options Code options ]AIM-ID ]AIM-ID Codabar normal mode (HA) Not check CD (4H) Not check CD (H7)
OPTICON Universal menu book Fig. 4.12. Modifiers for Code 11 Fig. 4.15. Modifiers for Aztec H* / X0 AIM/ISO15424 Code identifiers for : AIM/ISO15424 Code identifiers for : Code options ]AIM-ID Data structure ]AIM-ID Check 1 CD (BLG) No structure / other...
OPTICON Universal menu book 4.2.1. Set prefix _ZZ_ _RY_ All Codes _N1_ UPC-A _M0_ UPC-A + add on _N2_ UPC-E _M1_ UPC-E + add on _N3_ EAN-13 _M2_ EAN-13 + add on _N4_ EAN-8 _M3_ EAN-8 + add on _M4_...
Page 98
OPTICON Universal menu book _ZZ_ _MB_ S-Code _GL_ Matrix 2of5 _I8_ IATA _N0_ MSI/Plessey _L8_ Telepen _MA_ UK/Plessey _M9_ Code 128 _M8_ Code 93 _BLD_ Code 11 _*$_ Korean Postal Authority code _D5I_ Intelligent Mail Barcode _D6D_ POSTNET _OE_ GS1-Databar...
Page 99
OPTICON Universal menu book _ZZ_ _RR_ Composite codes _D4S_ Codablock F _MD_ DataMatrix _BF0_ Aztec _D4N_ Chinese Sensible code _MK_ QR Code _ML_ Maxicode _OC_ PDF417 _OD_ MicroPDF417 _MH_ ISO track 1 (IATA) _MI_ ISO track 2 (ABA) _MJ_ ISO track 3 (THRIFT)
OPTICON Universal menu book 4.2.2. Set suffix _ZZ_ _RZ_ All Codes _N6_ UPC-A _O0_ UPC-A + add on _N7_ UPC-E _O1_ UPC-E + add on _N8_ EAN-13 _O2_ EAN-13 + add on _N9_ EAN-8 _O3_ EAN-8 + add on _O4_...
Page 101
OPTICON Universal menu book _ZZ_ _OB_ S-Code _GM_ Matrix 2of5 _I9_ IATA _N5_ MSI/Plessey _L9_ Telepen _OA_ UK/Plessey _O9_ Code 128 _O8_ Code 93 _BLE_ Code 11 _*%_ Korean Postal Authority code _D5J_ Intelligent Mail Barcode _D6E_ POSTNET _PQ_ GS1-Databar...
Page 102
OPTICON Universal menu book _ZZ_ _RS_ Composite codes _D4T_ Codablock F _PO_ DataMatrix _BF1_ Aztec _D4O_ Chinese Sensible code _PW_ QR Code _PX_ Maxicode _PY_ PDF417 _PZ_ MicroPDF417 _PT_ ISO track 1 (IATA) _PU_ ISO track 2 (ABA) _PV_ ISO track 3 (THRIFT)
OPTICON Universal menu book 4.3.1. Direct input keyboard keys _ZZ_ _8J_ _8K_ _8L_ _8M_ _8N_ _8O_ _8P_ _8Q_ _8R_ _8S_ _8T_ _8U_ _9X_ Backspace _ZZ_...
Page 104
OPTICON Universal menu book _ZZ_ _7H_ _7I_ RETURN _7Q_ Enter ( Numeric keypad ) _7J_ _7K_ Arrow down _7L_ Arrow up _7M_ Arrow right _7N_ Arrow left _7T_ <DEL> _VQ_ <INSERT> _VR_ <HOME> _VS_ <END> _7O_ Page up _ZZ_...
Page 105
OPTICON Universal menu book _ZZ_ _7P_ Page down _7U_ Left <Shift> _7W_ Left <Ctrl> _7Y_ Left <Alt> _$8_ Left <GUI> _7V_ Right <Shift> _7X_ Right <Ctrl> _7Z_ Right <Alt> _$9_ Right <GUI> _9S_ CAPSLOCK _ZZ_...
OPTICON Universal menu book 5.1. Read mode options The following read modes are available: Trigger repeat: This option makes it more easy to select a Single read: single bar code from a sheet filled with bar When a bar code has been decoded, the codes.
Page 120
OPTICON Universal menu book 5.1. Read mode options _ZZ_ _S0_ Single read _S1_ Multiple read _S2_ Continuous read _S7_ Disable trigger _S8_ Enable trigger _XA_ Add-on wait mode disabled _XB_ Add-on wait mode 0.25 sec. _XC_ Add-on wait mode 0.50 sec.
OPTICON Universal menu book 5.1.1. Multiple read reset time This option can be used in conjunction with duration of each frame is variable, and is multiple read mode. dependent of the captured image. See figure • for Laser and CCD readers, it sets the time 5.01.
OPTICON Universal menu book 5.1.2. Quiet zone options With this option the reader can decode bar codes that have smaller start and/or end margins than specified for the symbology. Be careful when using this option. It may increase the possibility of partial reads and ghost reads.
OPTICON Universal menu book 5.1.3. Auto trigger options 5.2. Read time options These options are used to activate the auto The length of the period that the reader is ON trigger option of the reader. This is only after the trigger switch is pressed, or (in...
OPTICON Universal menu book 5.3. Power control The motor options are only applicable for selected laser bar code readers and with trigger enabled. In case the read time is expired, the motor can be switched OFF. In case the trigger is activated, the motor is switched ON again.
OPTICON Universal menu book 5.4. Redundancy This is the number of times that a label must be correctly decoded before it is transmitted. Selecting a higher redundancy count makes reading slower, but it reduces the probability of reading errors, especially when labels of poor definition are used.
OPTICON Universal menu book 5.5. Positive and negative bar codes Usually bar codes are printed black on white, but sometimes white on black. These labels are called positive and negative respectively. In case the 'negative bar codes' option has been selected, positive labels may not be decoded anymore or with difficulty.
OPTICON Universal menu book 5.6. Floodlight and aiming options The floodlight and aiming options affect the If an aiming light is available, the bar code light source that illuminates the area of the bar reader can generate an aiming pattern to help code symbol.
OPTICON Universal menu book 6.1. Buzzer settings These options determine the buzzer type, tone, Buzzer after transmission: duration and loudness. The buzzer tone and The good read buzzer will be activated after loudness are reader dependent due to different transmission.
OPTICON Universal menu book 6.2. Good read LED The Good Read LED can be disabled or set for several durations. _ZZ_ _T4_ Disable indicator _T5_ Indicator duration: 0.2 s _T6_ Indicator duration: 0.4 s _T7_ Indicator duration: 0.8 s _ZZ_...
OPTICON Universal menu book 7. MISCELLANEOUS 7.1. Diagnostics The options in this part are primarily intended for diagnostic purposes. The following options are available: Transmit software version: The software version is transmitted. Transmit ROM checksum: The software calculated checksum over the internal program is transmitted.
OPTICON Universal menu book 7.2. Serial configuration support Disable configuring via RS232: Error message - No label: The reader ignores all configuration commands Following this menu label a maximum of 4 from the RS232 port. The trigger and buzzer direct input characters may be read. These commands are still accepted.
Page 136
OPTICON Universal menu book 7.2. Serial configuration support _ZZ_ _TS_ Disable configuring via RS232 _TT_ Enable configuring via RS232 _8B_ Disable trigger via RS232 _8C_ Enable trigger via RS232 _WB_ Disable buzzer via RS232 _WA_ Enable buzzer via RS232 _TY_...
Page 137
OPTICON Universal menu book _ZZ_ _TH_ Error message No label _TI_ Error message No decode _ZZ_ U130...
OPTICON Universal menu book A. TROUBLE SHOOTING The trouble shooting diagram can be of help if your reader does not operate as expected. If any problem is not covered or solved with this diagram you need to contact your dealer.
OPTICON Universal menu book B. GLOSSARY OF TERMS AIM: Bluetooth: An acronym for Association for Automatic A wireless transmission protocol that uses Identification and Mobility. This is referring to an radio frequency waves. More information on organization that is an authority for standards bluetooth can be found on the Internet site: for bar codes.
Page 140
OPTICON Universal menu book CMOS imager: Emulation: A scanning device, which uses the CMOS The imitation of all or part of one device by technology. CMOS is an acronym for another so that the mimicking device can Complementary Metal Oxide Semiconductors.
Page 141
OPTICON Universal menu book IEEE 802.15.4: Parity: A wireless transmission protocol that uses A method of checking for errors in transmitted radio frequency waves. data. The eight bits of each transmitted character are added, and the total must always Intensity:...
Page 142
The exact may be represented. data format and protocol are not defined by this standard. All Opticon products use ASCII for Trigger: the data format. All handheld and stationary A signal that initiates an action or a series of readers use plain text protocol.
Page 146
OPTICON Universal menu book Example C.07. Example C.08. IATA MSI/Plessey (with MOD 10 Checksum) 1234567890 02468 encoded data: 024687 Example C.09. Example C.10. UK/Plessey Telepen Telepen numeric (Telepen ASCII) 02468 encoded data: 02468F8 57748174857483 Telepen ASCII data: Telepen Example C.11.
Page 147
OPTICON Universal menu book Example C.15. Example C.16. POSTNET Intelligent Mail Barcode 2132035356 12 001 987654 321600500 21320 0035 encoded data: 21320-3535 Example C.17. Example C.18. Composite Codes GS1 Databar Composite GS1 Databar Component A 0165473728281919 encoded data: 65473728281919 encoded RSS-14 data:...
Page 148
OPTICON Universal menu book Example C.19. Example C.20. (ECC200) Codablock F DataMatrix Codablock F sample bar code DataMatrix sample bar code. Example C.21. (Aztec) (Aztec Runes) Aztec encoded data: Aztec sample bar code. Example C.23. Example C.22. Chinese Sensible code...
Page 149
OPTICON Universal menu book Example C.25. Example C.26. PDF417 MicroPDF417 MicroPDF417 sample bar code. PDF417 sample bar code. U142...
Page 150
This card belongs to the universal menu book You can take out this card and pull out the window. The window spares out one bar code while masking all the other.
Need help?
Do you have a question about the UNIVERSAL MENU BOOK and is the answer not in the manual?
Questions and answers