Configuration; How To Configure The Scan Engine With Commands; Command Packet; Figure 3: Mek-3100 Evaluation Board - Opticon MDI-4000 Series Serial Interface Manual

Low profile, high-performance, 2d imager engine
Table of Contents

Advertisement

MDI-4000 Series Serial Interface Manual

Figure 3: MEK-3100 Evaluation Board

Figure 4: MEK-3100 Evaluation Board Kit

3 Configuration

This chapter explains the scan engine configuration, default setting and saving setting, and
basic commands.

3.1 How to Configure the Scan Engine with Commands

You can configure the scan engine by sending commands through the serial interface or by
reading 1D or 2D menu labels. This section describes the serial commands.
3.1.1

Command Packet

This table defines the command packet from header to terminator.
*2
Command Header
<ESC>
(0x1B)
*1
Except for single digit IDs, you can send multiple command IDs between a single header and terminator.
*2
You can also send a combination of command header <STX>(0x02) and terminator <ETX>(0x03).
6
*1
Command ID
None
1 - 2 digits (ASCII)
[(0x5B)
3 digits (ASCII)
Command Terminator
<CR>
(0x0D)
*2