Scale Indicator Programming (Continued)
Set Auto Power Off for Scale Indicator
To set the scale indicator's Auto Power Off see "Set Auto Power Off for Host Indicator" on Page 66 in Host Indicator
Programming
Set Hold Enable for Scale Indicator
To set the scale indicator's Hold Enable see "Set Hold Enable for Host Indicator" on Page 66 in Host Indicator Programming
Set RS232 Port Baud Rate
To set the scale indicator's RS232 Port Baud Rate see "Set RS232 Port Baud Rate" on Page 67 in Host Indicator Programming
Calibration Menu System
The following options are accessible through the calibration menu system:
Display
Calibration Step Code Default is 000 This continues through the main calibration menu There
Set Radio Enable
To set the scale indicator's Radio Enable see "Set Radio Enable" on Page 68 in Host Indicator Programming
Set Radio Channel
To set the scale indicator's Radio Channel see "Set Radio Channel" on Page 68 in Host Indicator Programming
Set Radio Channel Network ID
To set the scale indicator's Radio Channel Network ID see "Set Radio Channel Network ID" on Page 69 in Host Indicator
Programming
72
Function
are no user serviceable Calibration Sub menus
Radio Enable
Allows the host indicator to communication wirelessly with other
compatible equipment and devices
Radio Channel
Sets the radio channel when the radio is enabled There are 12 radio
channels available
Radio Network ID
Sets the radio's network identification (0-65534) for the radio channel
being used
Radio Encryption
Turning on the radio encryption makes the transmitted signal unable to be
Enable and Key
decoded without the receiver having the same encryption key (encryption
key value range: 0-65534) NOTE: IF YOU FORGET THE ENCRYPTION
KEY VALUE, YOU WILL NOT BE ABLE TO CONNECT A RECEIVING
DEVICE
Restore Radio
Default is 0 This leaves the radio settings as they have been programmed
Defaults
Entering 3 will restore the radio settings to their default values
Unit Switch Enable
Allows the changing of weighing units from pounds (lbs) to kilograms (kg)
through the main menu
Auto Zero Tracking
Automatic adjustment to the scale should the zero reading drift from the
set zero of the scale
Graduation Size
Set weighing incremental count Available increments: 1, 2, 5, 10, 20, 50,
and 100 units (lbs or kg)