BALZER FIELD FLOATER 6 User Manual page 69

Table of Contents

Advertisement

WEIGH SYSTEM PROGRAMMING
Host Indicator Programming (Continued)
Set Display Backlight
The following steps will set the backlight of the LCD display
Step
Set LCD display backlight
Select backlight option
Select your backlight option
Set Weighing Units
The following steps will set the weighing units for recorded and displayed data The scale will read in 10 lbs/5 kg increments
Step
Set Weighing Units
Select weighing unit options
Select your weighing unit option
Adjust Average Rate
The following steps will set the rate at which the Scale indicator takes a weight reading from each load cell The rate number
displayed is the number of 1/4 seconds between readings The lower the number, the more frequently a reading is taken
Step
Set Average Rate
Select Average Rate interval
Use numeric keypad to enter new rate
Accept your new rate
Field Floater 6 Grain Cart User Manual
Button
Entry Option
The default selection is for leaving the
backlight in Automatic This uses a light
sensor on the front of the panel to turn the
backlight on or off - display will be flashing
Backlight always Off
Backlight always On
Button
Entry Option
The default selection is pounds (lbs) - lbs
display will be flashing
Switch to kilograms (kg) - kg display will be
flashing
Changing this setting will make the same
change on the Scale Indicator
Button
Entry Option
The default selection is 10 - this will read
each load cell every 2 1/2 seconds
The scale indicator can accept a read
rate from 1 to 120 (every 1/4 second to 30
seconds) - setting the rate to 1 may give the
appearance of a constantly changing scale
Changing this setting will make the same
change on the Scale Indicator
Display
Display
Display
65