TROUBLESHOOTING
Scale Indicator Not Working/Error Codes (Continued)
Error
Load Cell Number
Code
6 5 4 3 2 1
- - - E E -
06
- - - E E E
07
- - E - - E
09
- - E - E -
0A
- - E - E E
0b
- - E E - -
0C
- - E E - E
0d
- - E E E -
0E
If the error code is indicating a load cell issue, the load cell can be checked with an ohm meter to determine if it has failed and
needs to be replaced Figure 77 shows the pin configuration of the load cell connector
Using an ohm meter, first measure the resistance between Pin A and Pin C This reading should be 700 ohms ±4 ohms (Figure
78)
Then measure the resistance between Pin B and Pin D This reading should be 775 ohms ±5 ohms (Figure 79)
FIGURE 78
A
Field Floater 6 Grain Cart User Manual
Error
Load Cell Number
Code
6 5 4 3 2 1
- E E - - -
18
- E E - - E
19
- E E - E -
1A
- E E - E E
1b
- E E E - -
1C
- E E E - E
1d
- E E E E -
1E
- E E E E E
1F
C
Error
Load Cell Number
Code
6 5 4 3 2 1
E - E - - E
29
E - E - E -
2A
E - E - E E
2b
E - E E - -
2C
E - E E - E
2d
E - E E E -
2E
E - E E E E
2F
E E - - - -
30
FIGURE 77
D
Error
Load Cell Number
Code
6 5 4 3 2 1
E E E - - E
39
E E E - E -
3A
E E E - E E
3b
E E E E - -
3C
E E E E - E
3d
E E E E E -
3E
E E E E E E
3F
FIGURE 79
B