Automatic Oiler Not Working (Continued)
3
If the line(s) do not "twitch":
A
Check to see if the tractor's hydraulics are engaged
B
Check the hydraulic connection to the pump for damage or leaks and replace if needed
C
Remove the manifold fitting from the pump and check for debris or damage (Figure 74) Have something
ready to plug the port so excessive oil does not leak out the port
4
If the Automatic Oiler still is not working, call Balzer's Service Department at 1-800-795-8551 Ext 134 (or press 0 for
the operator)
5
For replacement parts, call Balzer's Parts Department at 1-800-795-8551 Ext 104 (or press 0 for the operator)
Abnormal Auger Vibrations When Unloading
1
Check the upper vertical auger to make sure it is fully extended (Figure 75) Any gap where the two halves come
together may indicate the vertical auger drive couplers are not fully engaging each other, requiring the clevis on the
hydraulic fold cylinder to be adjusted (Figure 76)
2
Check the drive chains for proper tension (see "Auger Drive System" on Page 46 for drive chain tension maintenance)
3
Check the drive chains and sprockets for damage and replace if necessary
4
If the abnormal vibration is still occurring, call Balzer's Service Department at 1-800-795-8551 Ext 134 (or press 0 for
the operator)
52
FIGURE 75
Upper Vertical Auger not
fully extended
TROUBLESHOOTING
FIGURE 74
Hydraulic Fold Cylinder
Clevis
FIGURE 76