BALZER FIELD FLOATER 6 User Manual page 50

Table of Contents

Advertisement

Auger Drive System
Before Start of Season/Every 40 Hours of Use
1
Check the horizontal and vertical auger drive chains for proper tension (Figure 67) The tension should be adjusted for
a maximum of 1/2" (12mm) deflection to the longest straight section of chain (Figure 68)
A
To increase drive chain tension, loosen both the side bolt of the tensioner and the locking nut on the tension
bolt, then turn the tension bolt clockwise until proper tension is obtained Once proper tension is set, tighten
both the side bolt and the locking nut DO NOT OVERTIGHTEN THE SIDE BOLT
B
To decrease drive chain tension or to replace drive chain, loosen both the side bolt of the tensioner and the
locking nut on the tension bolt, then turn the tension bolt counter-clockwise until proper tension is obtained
Once proper tension is set, tighten both the side bolt and the locking nut DO NOT OVERTIGHTEN THE SIDE
BOLT
NOTE: The above images show the horizontal auger engagement system removed This does not need to be done to adjust drive chain tension It has been removed from these drawings to allow
necessary detail to be visible
46
FIGURE 67
Horizontal Auger
Drive Chain
Vertical Auger
Drive Chain
Vertical Drive
Chain Tensioner
FIGURE 68
Maximum 1/2"
Deflection
Rotate Tension Bolt
Clockwise to Increase
Tension on Drive Chains
Tensioner Locking Nut
MAINTENANCE
Horizontal Drive
Chain Tensioner
Field Floater 6 Grain Cart User Manual