BALZER FIELD FLOATER 6 User Manual page 74

Table of Contents

Advertisement

Host Indicator Programming (Continued)
Set for Weigh Unit Changeable in Main Menu
The following steps will set the indicator so the weighing units (lbs or kg) can be switched in the main menu mode
Step
Set Weigh Unit Changeable
Select No or Yes
Accept your selection
Set Auto Zero Tracking
The following steps will set the indicator to automatically adjust the zero of the scale should it drift within the set range from the
set zero and hold that drift for a preset amount of time
Example 1: AZT, by default, is set to 1 d (the "d" indicates the multiplier to the Graduation Size) and the Graduation Size,
by default is set to 10 Should the empty weight, where you zeroed the scale, drift up to ±10 weighing units and hold that
difference, the scale will automatically set that as the new zero weight
Example 2: AZT is changed to be 5 d and the Graduation Size is set at 10, should the empty weight, where you zeroed the
scale, drift up to ±5 weighing units and hold that difference, the scale will automatically set that as the new zero
Step
Set Auto Zero Tracking Range
Select Range
Accept your selection
Set Graduation Size
The following steps will set the scale to weight increment to display
Step
Set Graduation/Incremental Size
Select Increment
Accept your selection
70
WEIGH SYSTEM PROGRAMMING
Button
Entry Option
The default selection is Yes - display will be
flashing
Switch to No to lock the weighing units
Button
Entry Option
The default selection is 1d - display will be
flashing
Cycle through available range options: 1 d,
3 d, 5 d, Off, or 6 d
Button
Entry Option
The default selection is 10 - display will be
flashing
Cycle through available incremental
amounts: 1, 2, 5, 10, 20, 50, or 100
Display
Display
Display
Field Floater 6 Grain Cart User Manual

Advertisement

Table of Contents
loading

Table of Contents