Scale Indicator Not Working/Error Codes
1
Scale indicator does not want to power up after pressing the power button:
A
Check that the host indicator is turned on
B
Check the PWR/COM connection on the bottom of the indicator
C
Check the PWR/COM connection on the bottom of the host indicator
D
Check electrical connection at the 12VDC switched source
E
Check the PWR/COM cable for any breaks or damage and replace if necessary
2
Scale indicator showing error code:
Display
Internal Programming
Detected at Power Up
Analog/Digital Circuit
Load Cell Conversion Chart
When receiving an LCb or an LC error, find the corresponding error code on the table below to identify the load cell(s) causing
the error A letter "E" below the Load Cell Number indicates that load cell is causing an error with the scale indicator and needs
to be checked
Error
Load Cell Number
Code
6 5 4 3 2 1
- - - - - E
1
- - - - E -
2
- - - E - -
3
- - E - - -
4
- E - - - -
5
E - - - - -
6
- - - - E E
03
- - - E - E
05
54
Problem
Calibration programming is stored in a permanent memory area This
Lost or Corrupted
code indicates an error in the stored settings Attempt to recalibrate the
indicator If error still present after recalibration, the indicator will need to
be replaced
Weighing Capacity
The scale indicator is over the maximum weight capacity This typically
Error
indicates either a load cell issue or a cable issue Checking the scale
indicator will determine which load cell(s) have lost communication with
the scale indicator
Low Battery
The supply voltage to the indicator is below proper operating level Check
all power connections and source voltage
Unable to Display
The number that is wanting to be displayed has too many characters for
Value
the display to show The typical cause of this error is zeroing out the scale
with a full load so when the load is emptied, the negative number has too
many characters Zeroing the scale will clear this error
Load Cell Error
A load cell may have failed or a bad connection exists between the load
cell and the scale The number will show which cell(s) to check See the
Load Cell Conversion Chart below for cell failure code
Check cables and connections between indicated load cells
Load Cell Error
A load cell may have failed or a bad connection exists between the load
Detected during
cell and the scale The number will show which cell(s) to check See the
Operation
Load Cell Conversion Chart below for cell failure code
Check cables and connections between indicated load cells
The analog to digital circuit board inside the indicator has failed and needs
Board Failure
to be repaired or replaced
Error
Load Cell Number
Code
6 5 4 3 2 1
- - E E E E
0F
- E - - - E
11
- E - - E -
12
- E - - E E
13
- E - E - -
14
- E - E - E
15
- E - E E -
16
- E - E E E
17
TROUBLESHOOTING
Definition
Error
Load Cell Number
Code
6 5 4 3 2 1
E - - - - E
21
E - - - E -
22
E - - - E E
23
E - - E - -
24
E - - E - E
25
E - - E E -
26
E - - E E E
27
E - E - - -
28
Field Floater 6 Grain Cart User Manual
Error
Load Cell Number
Code
6 5 4 3 2 1
E E - - - E
31
E E - - E -
32
E E - - E E
33
E E - E - -
34
E E - E - E
35
E E - E E -
36
E E - E E E
37
E E E - - -
38