Wiring Instructions (Hardwired Hcs) - ClipperCreek HCS User Manual

Hide thumbs Also See for HCS:
Table of Contents

Advertisement

WIRING INSTRUCTIONS (Hardwired HCS)

Route the HCS conduit to a nearby junction box. Use the included
½" trade size watertight conduit fitting and sealing washer to
provide a moisture-resistant seal between the conduit fitting
and the junction box. If necessary, drill a ⅞" diameter hole to
accommodate the conduit fitting. For outdoor installations, ensure
the junction box is fully sealed using appropriate electrical grade
silicone sealant.
Figure 9: Wiring the
HCS in a Junction Box
Before connecting the HCS service
conductors, please carefully read the
section of this manual titled Installation -
Service Connections. If unsure of the type
of power provided at the service panel,
please consult with the local utility or
call a Service Representative for
assistance.
The three supplied HCS-15, 20, 25, 30 or
40 service conductors use stranded 10
AWG 90ºC copper wire. The three
supplied HCS-50, HCS-60, and HCS-80
service conductors use stranded 8 AWG,
90ºC copper wire.
The insulation of each conductor is color
coded for standard 240V AC installation:
Green:
Ground
Black:
Line 1 (120V AC to Ground)
Red:
Line 2 (120V AC to Ground)
Les trois HCS-15, 20, 25, 30 un HCS-40
service conducteurs fournis utilisent
bloqués câble en cuivre 10 AWG 90ºC.
31