(Hardwired EV)
Route the EV conduit to a nearby junction box. Use the included ½" trade size
watertight conduit fitting and sealing washer to provide a moisture-resistant seal
between the conduit fitting and the junction box. If necessary, drill a 7/8"diame- ter
hole to accommodate the conduit fitting. For outdoor installations ensure the junction
box is fully sealed using appropriate electrical grade silicone sealant.
Before connecting the EV service conductors, please carefully read the section of this
manual titled Service Connections on page 9. If you are unsure of the type of power
provided at the service panel, please consult with your local utility or call your Service
Representative for assistance.
Figure 8. Wiring the EV in a junction box
The three supplied EV-20, 25, 30 or 40 EV-40 service
conductors use stranded 10 AWG 75ºC copper wire.
The three supplied EV-50, and EV-60 service con-
ductors use stranded 8 AWG, 75ºC copper wire.
The insulation of each conductor is color coded for
standard 240VAC installation:
Green:
Ground
Black:
Line 1 (120VAC to Ground) Red:
(120VAC to Ground)
Les trois EV-20, 25, 30 un EV-40 service conduc- teurs
fournis utilisent bloqués câble en cuivre 10 AWG 75ºC.
Les trois EV-50 fournis et conducteurs EV-60 uti-
lisent des services bloqués 8 fil de cuivre AWG, 75ºC.
L'isolation de chaque conducteur est un code couleur
pour l'installation de 240VAC norme:
Vert:
Mise à la Terre
Noir:
Ligne 1 (120VAC à Mise à la Terre) Rouge:
Ligne 2 (120VAC à Mise à la Terre)