AT commands
Diagnostic commands
The following AT commands are diagnostic commands. Diagnostic commands are typically volatile and
will not persist across a power cycle.
%H (MAC Unicast One Hop Time)
The MAC unicast one hop time timeout in milliseconds. If you change the MAC parameters it can
change this value.
Parameter range
[read-only]
Default
N/A
0x267
%V (Board Voltage)
Reads the supply voltage to the module's VCC (pin 2).
The conversion of the hex value returned by %V to Volts is VAL/65536 = Volts.
Example:
2.8 VDC = 2.8 * 65536 = 0x2CCCD
3.3 VDC = 3.3 * 65536 = 0x34CCD
Parameter range
[read-only]:
0x26666 - 0x39999 (2.40 to 3.60 V)
Default
N/A
%8 (MAC Broadcast One Hop Time)
Parameter range
[read-only]
Default
N/A
BC (Bytes Transmitted)
The number of RF bytes transmitted. The firmware counts every byte of every packet, including
MAC/PHY headers and trailers. The purpose of this count is to estimate battery life by tracking time
spent performing transmissions.
This number rolls over to 0 from 0xFFFF.
You can reset the counter to any unsigned 16-bit value by appending a hexadecimal parameter to the
command.
XBee®/XBee-PRO XTend Compatible (XTC) DigiMesh RF Module User Guide
Diagnostic commands
42