Digi XBee XTC User Manual page 91

Digimesh radio frequency (rf) module
Hide thumbs Also See for XBee XTC:
Table of Contents

Advertisement

API frames
Format
The following table provides the contents of the frame. For details on frame structure, see
specifications.
Frame data
fields
Frame type
64-bit source
address
Reserved
Receive
options
Reserved
64-bit remote
address
NI string
Reserved
Device type
Source event
Digi Profile ID
Digi
Manufacturer
ID
Digi DD value
(optional)
RSSI (optional)
XBee®/XBee-PRO XTend Compatible (XTC) DigiMesh RF Module User Guide
Offset Description
3
0x95
MSB first, LSB last. The sender's 64-bit address.
4-11
12-13
Reserved.
Bit field:
14
0x00 = Packet acknowledged
0x01 = Packet was a broadcast packet
0x06, 0x07:
b'01 = Point-Multipoint
b'10 = Repeater mode (directed broadcast)
b'11 = DigiMesh
Ignore all other bits
Reserved.
15-16
17-24
Indicates the 64-bit address of the remote device that transmitted the
Node Identification Indicator frame.
25-26
Node identifier string on the remote device. The NI string is terminated
with a NULL byte (0x00).
Reserved.
27-28
0 = Coordinator
29
1 = Normal Mode
2 = End Device
For more options, see
1 = Frame sent by node identification pushbutton event.
30
31-32
Set to the Digi application profile ID.
33-34
Set to the Digi Manufacturer ID.
Reports the DD value of the responding device. Use the NO command to
35-38
enable this field.
39
Received signal strength indicator. Use the NO command to enable this
field.
Node Identification Indicator frame - 0x95
NO (Network Discovery
Options).
API frame
91

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xbee-pro xtc

Table of Contents