API frames
Frame data fields
Frame type
Status
Example
When a device powers up, it returns the following API frame.
Frame data fields
Start delimiter
Length
LSB 2
Frame type
Status
Checksum

Transmit Status frame - 0x8B

Description
When a Transmit Request (0x10, 0x11) completes, the device sends a Transmit Status message out of
the serial interface. This message indicates if the Transmit Request was successful or if it failed.
Note
Broadcast transmissions are not acknowledged and always return a status of 0x00, even if the
delivery failed.
Format
The following table provides the contents of the frame. For details on frame structure, see
specifications.
Frame data
fields
Frame type
Frame ID
16-bit
destination
address
XBee®/XBee-PRO XTend Compatible (XTC) DigiMesh RF Module User Guide
Offset Description
3
0x8B
4
Identifies the serial interface data frame being reported. If Frame ID = 0 in
the associated request frame, no response frame is delivered.
5
The 16-bit Network Address where the packet was delivered (if
successful). If not successful, this address is 0xFFFD (destination address
6
unknown).

Transmit Status frame - 0x8B

Offset
Description
3
0x8A
4
Offset
Example
0
0x7E
MSB 1
0x00
LSB 2
0x02
3
0x8A
4
0x00
5
0x75
API frame