Chapter 11 Protocol Decoding
Endian
Press Endian to select "LSB" or "MSB". By default, it is "MSB".
Polarity setting
Press Data Polarity continuously to select Positive
the polarity for data decoding.
5. Display-related setting
Press Display to enter the display setting menu.
Set the display format
Press Format, rotate the multifunction knob
format of the bus data. Then, press down the knob to select it. You can also
press Format continuously or enable the touch screen to select it. The
available display formats of the bus data are "Hex", "Dec", "Bin", and
"ASCII".
Adjust the vertical position of the bus
Press Position, and then rotate the multifunction knob
vertical display position of the bus.
Set the label display
Press Label to enable or disable the label display of the I2S decoding bus.
When enabled, the bus label "I2S" will be displayed at the upper-left side of
the bus (when the bus display is enabled).
Event table
Press Event Table to enter the event table setting menu. The event table
displays the detailed decoding information in time order in the form of a
table, so as to better observe the long decoded data. The decoding
information includes the decoded left channel data, right channel data, the
corresponding line number, and time.
Open or close the event table: Press Event Table continuously to
enable or disable the event table. When you enable the event table,
the following figure is displayed, as shown in Figure 11-14. You can
also enable the touch screen to tap the icon
corner of the table to close the event table. Besides, when the
operating status is "STOP", you can also rotate the multifunction knob
to select a specified line and view the corresponding decoding
information.
MSO5000-E User Guide
or Negative
to select the display
to adjust the
at the upper-right