Rigol MSO5000-E Series User Manual page 219

Digital oscilloscope
Hide thumbs Also See for MSO5000-E Series:
Table of Contents

Advertisement

Chapter 11 Protocol Decoding
Adjust the vertical position of the bus
Press Position, and then rotate the multifunction knob
vertical display position of the bus.
Set the label display
Press Label to enable or disable the label display of the RS232 decoding
bus. When enabled, the bus label "RS232-TX" and/or "RS232-RX" will be
displayed at the upper-left side of the bus (when the bus display is
enabled).
Event table
Press Event Table to enter the event table setting menu. The event table
displays the detailed decoding information in time order in the form of a
table, so as to better observe the long decoded data. The decoding
information includes the decoded data (Tx and/or Rx), the corresponding
line number, time, and error information (Tx and/or Rx).
Note:
When the Tx and Rx source channels are set to "OFF", information of
the data line is not displayed in the data table.
Open or close the event table: Press Event Table continuously to
enable or disable the event table. You can also enable the touch screen
to tap the icon
event table. Besides, when the operating status is "STOP", you can also
rotate the multifunction knob
the corresponding decoding information.
Note:
Set the event table format: Press Format, rotate the multifunction
knob
event table. Then, press down the knob to select it. You can also press
Format continuously or enable the touch screen to select it. The
available formats include "Hex", "Dec", "Bin", and "ASC".
Set the view type: Press View, then rotate the multifunction knob
to select the form of the event table to be viewed. Press down the knob
to select it. You can also press View continuously or enable the touch
screen to select it. The available choices include "Packets", "Details",
and "Payload". You can also tap "Packets", "Details", or "Payload" at
MSO5000-E User Guide
at the upper-right corner of the table to close the
When you adjust the horizontal timebase, the waveform displayed
on the screen will also change, and the total number of lines
containing the decoding information in the event table will also be
changed.
The displayed decoded data information in the bus is related to the
value of the horizontal timebase. Reducing the horizontal
timebase can help you view the detailed information.
to select the display format of "Data" (Tx and/or Rx) in the
to select a specified line and view
RIGOL
to adjust the
11-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents