OceanStor Dorado V3 Series
Parts Replacement
Step 7 Optional: Pull the information plate of the system subrack. (If you face the front part of the
system subrack, the information plate is located at the lower right of the enclosure, as shown
in
Figure
the device information label to the information plate. Then, push the information plate back to
the enclosure.
Figure 5-20 Position of the information plate
Step 8 Install the system subrack into the cabinet, as shown in
1.
2.
3.
Issue 05 (2019-01-30)
NOTE
l Two different nameplates are included in the product. Select the one that contains identical
information to the nameplate on the removed system subrack.
l When attaching the product model label and Intel label, attach the product model label first and then
attach the Intel label under the information on the product model label.
5-20. Gently pull the information plate, but not away from the enclosure.) Attach
NOTE
You can attach the device information labels to both the front and back of the information plate. The
label content and positions must be the same as those on the replaced system subrack. If a label has been
attached to one side of the information plate, you only need to attach the device information label with a
QR code to the other side of the information plate. Attaching the device information plate helps
engineers easily identify and maintain devices.
Slide the system subrack into the cabinet along guide rails.
Use M6 screws to fix the system subrack in the cabinet.
Ensure that the system subrack is horizontally installed and tightly screwed.
Copyright © Huawei Technologies Co., Ltd.
5 Replacing FRUs
Figure
5-21.
89