Huawei OceanStor Dorado V3 Series Parts Replacement page 111

Hide thumbs Also See for OceanStor Dorado V3 Series:
Table of Contents

Advertisement

OceanStor Dorado V3 Series
Parts Replacement
Figure 5-31 Installing a disk module
Step 7 Wait about two minutes and check the status of the Running and Alarm/Location indicators
on the disk module to determine whether the disk module is successfully installed.
5-32
l
l
Issue 05 (2019-01-30)
shows the locations of the Running and Alarm/Location indicators.
If the Running indicator is steady on and the Alarm/Location indicator is off, the disk
module is successfully installed.
If the Running indicator is off or the Alarm/Location indicator is steady on, the newly
installed disk module is faulty, the disk module slot is faulty, or the disk module is
incorrectly installed.
Copyright © Huawei Technologies Co., Ltd.
5 Replacing FRUs