Huawei OceanStor Dorado V3 Series Parts Replacement page 50

Hide thumbs Also See for OceanStor Dorado V3 Series:
Table of Contents

Advertisement

OceanStor Dorado V3 Series
Parts Replacement
Precautions
l
l
l
l
Tools and Materials
l
l
l
Procedure
Step 1 Perform a pre-replacement check.
Check whether there is a redundant BBU and whether the Running/Alarm indicator of the
BBU is steady green, as shown in
components, see
Figure 4-43 Running/Alarm indicator on a BBU
You can perform replacement only when a redundant BBU exists and the redundant BBU is
working properly.
Step 2 Wear an ESD wrist strap.
Step 3 Press the latch on the BBU to release the handle and pull out the BBU, as shown in
4-44.
Issue 05 (2019-01-30)
NOTE
You can locate a component in either of the following ways:
l Locating a component based on alarms in DeviceManager: On the Alarms and Events page
of DeviceManager, view the help information and locate the component to be replaced.
l Locating a component based on the status of its Running/Alarm indicator: For details about the
indicators on different components, see
BBUs, and Fan
Modules.
Remove and insert a BBU with even force. Excessive force may damage the appearance
or connectors of the BBU.
Remove only one BBU at a time.
When a BBU is being replaced, the storage system does not have BBU redundancy.
Therefore, you are advised to replace a BBU as quickly as possible.
A BBU must be replaced within five minutes. Otherwise, the system heat dissipation is
compromised.
ESD wrist strap
ESD bag
Labels
Running/Alarm Indicators on a Dorado6000 V3 Controller
Copyright © Huawei Technologies Co., Ltd.
4.4 Running/Alarm Indicators on Power Modules,
Figure
4-43. For details about the indicators on different
4 Replacing CRUs
Enclosure.
Figure
42