OceanStor Dorado V3 Series
Parts Replacement
Figure 5-97 Installing a fan module
Step 7 Wait about two minutes and check the status of the Running/Alarm indicator on the fan
module to determine whether the fan module is successfully installed.
location of the Running/Alarm indicator.
l
l
Figure 5-98 Running/Alarm indicator on a fan module
Step 8 If the fan module is successfully installed, close the panel, as shown in
Issue 05 (2019-01-30)
If the indicator is steady green, the fan module is successfully installed.
If the indicator is steady red or off, the newly installed fan module is faulty, the fan
module slot is faulty, or the fan module is incorrectly installed.