Huawei OceanStor Dorado V3 Series Parts Replacement page 37

Hide thumbs Also See for OceanStor Dorado V3 Series:
Table of Contents

Advertisement

OceanStor Dorado V3 Series
Parts Replacement
Precautions
l
l
l
l
Tools and Materials
l
l
l
l
Procedure
Step 1 Perform a pre-replacement check.
Check whether there is a redundant power module and whether the Running/Alarm indicator
of the redundant power module is steady green, as shown in
the indicators on different components, see
Enclosure.
Figure 4-25 Running/Alarm indicator on a power module
You can perform replacement only when a redundant power module exists and the redundant
power module is working properly.
Issue 05 (2019-01-30)
NOTE
You can locate a component in either of the following ways:
l Locating a component based on alarms in DeviceManager: On the Alarms and Events page
of DeviceManager, view the help information and locate the component to be replaced.
l Locating a component based on the status of its Running/Alarm indicator: For details about the
indicators on different components, see
BBUs, and Fan
Modules.
Do not touch the connectors of a power module and a power cable.
Remove and insert a power module with even force. Excessive force may damage the
appearance or connectors of the power module.
Remove only one power module at a time.
A power module must be replaced within three minutes. Otherwise, the system heat
dissipation is compromised.
ESD wrist strap
ESD bag
Label
Phillips screwdriver
Copyright © Huawei Technologies Co., Ltd.
4.4 Running/Alarm Indicators on Power Modules,
Figure
Running/Alarm Indicators on a 2 U Disk
4 Replacing CRUs
4-25. For details about