Huawei OceanStor Dorado V3 Series Parts Replacement page 69

Hide thumbs Also See for OceanStor Dorado V3 Series:
Table of Contents

Advertisement

OceanStor Dorado V3 Series
Parts Replacement
Table 4-1 Indicators on the rear panel of a controller enclosure
No.
1
2
Running/Alarm Indicators on a Dorado6000 V3 Controller Enclosure
Figure 4-66
Figure 4-66 Indicators on the front panel of a controller enclosure
1
Table 4-2
Table 4-2 Indicators on the front panel of a controller enclosure
No.
1
Issue 05 (2019-01-30)
Indicator
Status and Description
Running/Alarm
l Steady green: The BBU is fully charged.
indicator on a
l Blinking green (1 Hz): The BBU is being charged.
BBU
l Blinking green (4 Hz): The BBU is being discharged.
l Steady red: The BBU is faulty.
Running/Alarm
l Steady green: The power module is working properly.
indicator on a
l Blinking green: The power input is normal but the device
power module
l Steady red: The power module is faulty.
l Off: No external power is input.
shows the indicators on the front panel of a controller enclosure.
Running/Alarm indicator on a
BBU
describes the indicators on the front panel of a controller enclosure.
Indicator
Status and Description
Running/Alarm
l Steady green: The BBU is fully charged.
indicator on a
l Blinking green (1 Hz): The BBU is being charged.
BBU
l Blinking green (4 Hz): The BBU is being discharged.
l Steady red: The BBU is faulty.
Copyright © Huawei Technologies Co., Ltd.
is powered off.
2
4 Replacing CRUs
Running/Alarm indicator on a fan
module
61