Figure 3-11 Ethernet Cable Connection to Termination Module
E 2018 Nordson Corporation
6. See Figure 3-11. Arrange the twisted pair wires in the module according
to the T568-B wiring scheme, with the ends at least 1/4 in. through the
terminals. Retain the twists in the wires as close to the terminals as
possible. Use a 110 punch-down tool to attach the wires.
7. Trim the ends of the wires as close to the termination module as
possible.
8. Install the retention caps on the termination module.
9. Crimp a ground lug to the shield wire.
10. Assemble the ethernet termination case as shown. For rear-connect
modules, snap the termination module into the bezel, then install the
bezel into the adapter.
Use Type T568B cables.
Use T568-B wiring scheme.
Rear-Connect Module
(End View)
Green
White/Green
Blue
White/Blue
Retention Cap
Module
Bezel
Cover
Shield
Adapter
Brown
White/Brown
Orange
White/Orange
Shield
Bezel
3-11