Configuration Procedure; Air And Powder Tubing Connections; Operation - Nordson Encore HD Powder Spray System with Prodigy Color-on-Demand Customer Product Manual

Table of Contents

Advertisement

Function 01, Value 00
Figure 4-5 Displaying and Changing Configuration Functions
Function
Number
F34
Conveyance Air Constant A
F35
Conveyance Air Constant C
F36
Pattern Air Constant A
F37
Pattern Air Constant C

Air and Powder Tubing Connections

E 2018 Nordson Corporation

Configuration Procedure

If you replace a control board or manifold, use this procedure to configure
the system.
Press and hold the Nordson button for 5 seconds. The
Function/Help display lights to show the function numbers and values. Use
the functions to configure the controller for your application. See Figure 4-5.
The function numbers are in the form F00−00 (Function Number−Function
Value).
To scroll through the function numbers rotate the knob. To select the
displayed function number, press the Enter button.
When the function is selected the function value blinks. To change the
function value, rotate the knob. Press the Enter button to save the change
and exit the value, so that rotating the knob now scrolls through the function
numbers.
Use the function controls F-34 through F-37 to set the conveyance air and
pattern air calibration values. See Table -2.
Table 4-2 Function Settings
Function
Name
See the Encore HD Manual Powder Spray System Controller manual for
more information on configuration settings.
See Figure 4-6 for the air and powder tubing connections for the pump and
manifold.
Function 01, Value 01
Function
Values
3.500 to 4.500
−0.500 to +0.500
1.500 to 4.500
−0.500 to +0.500
4-7

Operation

Default
HDLV Mode
4.000
0
4.000
0
Part 1605396-04