Figure 5-3 Inputs 1−16 Screen
Input
Channel
Code
1
SW1
2
RS1
3
CCS
4
CVB
5
PS1
6
DOC
7, 8
Spares
9
RS2
10
BIT 5
11
BIT 4
12
BIT 3
13
BIT 2
14
BIT 1
15, 16
Spares
E 2018 Nordson Corporation
Not Used
Remote Start 1: Signal from foot pedal pressure switch.
Color Change Status signal from pump control board.
Color Valve Back purge signal from pump control board.
Air pressure switch: prevents color change start if air pressure falls below
70 psi.
Dump Output Control signal from pump control board.
Remote Start 2: 24V remote start signal from customer device to PLC.
Binary 5 bit remote color selection inputs for colors 1 − 28 from customer
device to PLC:
BIT 1 = Least Significant Bit
BIT 5 = Most Significant Bit
Set the color selection bits first, then strobe RS2.
N/A

Outputs

Touching the Output screen buttons should light the LEDs on the PLC
output modules and on the corresponding solenoid valves, and send an air
signal to the appropriate valve bladder.
Troubleshooting
Function
5-5