Table of Contents

Advertisement

Quick Links

r
r
Encore
HD iControl
System
Hardware Manual
Installation, Troubleshooting, Repair, Parts
Part 1603054-02
Issued 4/15
For parts and technical support, call the Industrial Coating
Systems Customer Support Center at (800) 433-9319 or
contact your local Nordson representative.
This document is subject to change without notice.
Check http://emanuals.nordson.com for the latest version.
FM
C
US
APPROVED
NORDSON CORPORATION  AMHERST, OHIO  USA

Advertisement

Table of Contents
loading

Summary of Contents for Nordson Encore HD iControl System

  • Page 1 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative. This document is subject to change without notice. Check http://emanuals.nordson.com for the latest version. APPROVED NORDSON CORPORATION  AMHERST, OHIO  USA...
  • Page 2 Contact Us Notice This is a Nordson Corporation publication which is protected by copyright. Nordson Corporation welcomes requests for information, comments, and Original copyright date 2013. No part of this document may be inquiries about its products. General information about Nordson can be...
  • Page 3 Change Record Change Record Revision Date Change 03/13 Released 04/15 Removed part numbers from parts list. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 4 Change Record Part 1603054-02 E 2015 Nordson Corporation...
  • Page 5: Table Of Contents

    ........ESD Ground Procedures and Equipment ....Part 1603054-02 E 2015 Nordson Corporation...
  • Page 6 ....... . . Ribbon Cable Connections ......Part 1603054-02 E 2015 Nordson Corporation...
  • Page 7 ........Part 1603054-02 E 2015 Nordson Corporation...
  • Page 8 Table of Contents Part 1603054-02 E 2015 Nordson Corporation...
  • Page 9: Safety

    Regulations and Approvals Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for Nordson equipment will be voided if instructions for installation, operation, and service are not followed. All phases of equipment installation must comply with all federal, state, and local codes.
  • Page 10: Personal Safety

    Clean, maintain, test, and repair equipment according to the instructions in your equipment documentation. Use only replacement parts that are designed for use with original equipment. Contact your Nordson representative for parts information and advice. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 11: Grounding

    Disconnect and lock out electrical power. Close pneumatic shutoff valves and relieve pressures. Identify the reason for the malfunction and correct it before restarting the equipment. Disposal Dispose of equipment and materials used in operation and servicing according to local codes. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 12: Safety Labels

    See Figure 1-1 for the location of the safety labels. Item Part Description WARNING: Disconnect power before servicing. 1034161 WARNING ATTENTION Disconnect all Debranchez toutes power before les sources servicing. d'alimentation electrique avant d'entreprendre des travaux d'entretien. Figure 1-1 Safety Labels Part 1603054-02 E 2015 Nordson Corporation...
  • Page 13: System Overview

    1056418 Operator Card for all versions: 1024758 and this manual. An Encore HD iControl system console controls up to 32 automatic guns. Figure 2-1 Prodigy iControl Console Part 1603054-02 E 2015 Nordson Corporation...
  • Page 14: Console And System Hardware And Software

    Ethernet network and switch PLCs and VFDs 2nd Booth Option: 2nd booth shares encoder signal, zone and part ID signals, and if in/out positioners and reciprocators are used, scanner signals. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 15 2. 3-Position interlock switch 6. Card cage with gun control cards 10. I/O and interface cards 3. Computer and LCD display 7. Gun cable receptacles 11. I/O board 4. CompactFlash cards 8. Power switch Part 1603054-02 E 2015 Nordson Corporation...
  • Page 16: Operator Interface

    Use the Bypass position to set up and test spray gun settings. In the Lockout position, the guns and the gun movers are disabled. Use this position when working inside the booth. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 17: Can And Ethernet Networks

    This may require a trade off between desired conveyor speed and part tracking resolution (the higher the conveyor speed the coarser the tracking resolution). NOTE: A timer may be used instead of an encoder. Consult with your Nordson representative. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 18: Gun Control Cards

    Pollution Degree Installation (Overvoltage) Category II Environmental Operating Temperature 32−104 _F (0−40 _C) Operating Humidity 5−95%, non-condensing Hazardous Location Rating North America: Class II Division 2, Groups F & G European Union: Ex II 3D Part 1603054-02 E 2015 Nordson Corporation...
  • Page 19: Hdlv Pump And Spray Gun Pattern Air Quality

    Encore HD iControl Controllers over the ambient temperature range of +15 _C to +40 _C (59 _F to 104 _F). Approvals See Figure 2-4 for the approval labels affixed to the equipment. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 20 (2) 3 D Ex tc IIIB T60_ C T = +15 to +40_ C NORDSON CORP. AMHERST, OH. USA Vn = 100-230 Vac n = 50-60 Hz Pn = 600 VA OUTPUT: Vo (peak) = 19V Io (peak) = 1.0 A WARNING - POTENTIAL ELECTROSTATIC CHARGING HAZARD, SEE INSTRUCTION MANUAL.
  • Page 21: Approved Program And User Data Cards

    System Overview Approved Program and User Data Cards NOTE: Refer to the Parts section for the Nordson part number for the Compact Flash cards shipped with the system. CompactFlash card capacity: 512 Mb minimum − Type I CompactFlash only. NOTE: Retail CompactFlash refers to cards available at camera, computer, and electronic retail shops.
  • Page 22 2-10 System Overview Part 1603054-02 E 2015 Nordson Corporation...
  • Page 23: Installation

    Therefore, this section provides only basic installation information. Detailed information is contained in the system wiring diagrams, plan views, and other documentation furnished by Nordson application engineering. Once all hardware is installed and wired and the system is powered up, the operator interface is used to configure, setup, and operate the system.
  • Page 24: System Diagram

    (if used) are typically mounted on the Part ID stand. All other junction boxes are mounted on the booth, operator platforms, feed center, or gun movers, according to their function. Refer to your Nordson plan view and wiring drawings for locations and mounting details.
  • Page 25: Can Network Connections And Settings

    Next Card Manual Gun J-Box Manual Gun Controllers 1−4 BLACK WHT/BLUE Network/Power WHT/BLUE Cable BLUE BLUE WHT/BLUE NOTE: Set Manual Gun BLUE Controller SW1 TERM switch to OFF. SHIELD Figure 3-1 CAN Network Cable Connections Part 1603054-02 E 2015 Nordson Corporation...
  • Page 26: Icontrol Console Can Address And Termination Settings

    Manual gun controllers are shipped with their CAN termination switch set to ON. For each manual gun controller in the system: 1. Open the controller enclosure and locate SW1 on the controller interface board. 2. Set the TERM switch on SW1 to OFF. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 27: Pump Control Card Configuration

    Contact is open with power applied to console and no alarms present. Red, Orange Conveyor Interlock: 240 Vac, 1 phase, 6 mA (for 120 Vac, refer to instructions below) Part 1603054-02 E 2015 Nordson Corporation...
  • Page 28: Conveyor Interlock And Remote Lockout

    Lockout GRAY (120V) YELLOW 240V 240V BLACK Alarm YELLOW BROWN ORANGE BLUE Conveyor Interlock (120V) 240V 240V WHITE Figure 3-3 240 Vac (Factory) and 120 Vac (Optional) Conveyor Interlock and Remote Lockout Relay Connections Part 1603054-02 E 2015 Nordson Corporation...
  • Page 29: Grounding

    Electrostatic discharges occur at very high frequencies, around 100 megahertz. An ordinary ground conductor does not conduct such high frequencies well enough to prevent damage to electronic components. Special flat braided cables are provided with your Nordson powder coating equipment to protect against ESD. Part 1603054-02...
  • Page 30: Gun Current Path

    (gun driver board and power supply). Ground Braid Gun Current Path Ions iControl Booth Base Ground Braid Figure 3-4 Electrostatic Current Path Part 1603054-02 E 2015 Nordson Corporation...
  • Page 31: Esd Ground Procedures And Equipment

    ESD Grounding Procedures and Equipment Always use the special flat braided copper ESD ground cables furnished with all Nordson spray gun controllers to ground them. The ESD ground cables should always be attached to the welded booth base, not to a panel, enclosure, or other component bolted to the base.
  • Page 32: 25-Conductor Cable Connections

    Interlock WHITE from 19 LO Not Applicable Conveyor Front Panel Interlock 8 HI NOTE: For information on how to use Trigger Banks, see Using Zone Inputs for Direct Triggering in the iControl Software Manual. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 33: Switching Inputs To Sourcing

    SCNR2 cables to Part ID scanner. NOTE: The part ID scanner or photoeyes must be located so that the iControl system receives the part ID before the leading edge of the part breaks the zone scanners or photoeyes. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 34: Analog Scanner Connections

    (SCNR1) from the PEJB to the scanners. Maximum Analog Scanner Separation: 6 meters (20 ft) if scanner is less than 1.22 meters (4 ft) long 4.6 meters (15 ft) if scanner is greater than 1.22 meters (4 ft) long. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 35: Customer-Supplied Part Id System Connections

    The PLCs control the Variable Frequency Drives (VFDs) that power and control the gun mover motors according to the settings made in the iControl software. Oscillators are not controlled by the iControl software. The PLCs control their motion during color changes only. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 36 For the Ethernet portion of the wiring, M12 D-coded 4 pole cables with bulkhead connectors or plugs on each end are used. NOTE: Do not connect any device to the Ethernet network that is not approved by Nordson Technical Support or Engineering. iControl System Main Electrical...
  • Page 37: Gun Cable And Feed Tubing Connections

    Refer to the Parts section for seal and jumper part numbers. Receptacle #8 Bulkhead Seal Harnesses Gun Cables Jumper Install in #8 Card Receptacle Gun Card Figure 3-9 Seal and Jumper Installation − Example Showing 8 Gun System with 7 Guns Part 1603054-02 E 2015 Nordson Corporation...
  • Page 38: Program And User Data Cards

    Backup function. Refer to Data Backup in the iControl Operator Interface manual for instructions. NOTE: Not all CompactFlash cards are the same. For approved cards, order the cards listed in the parts section, or contact your Nordson controls engineer or Nordson Technical Support. Part 1603054-02...
  • Page 39: Touch Screen Calibration

    Refer to Troubleshooting for a complete description of the calibration procedure and instructions on calibration. System Upgrades Parts requirements for system upgrades depend on your existing system configuration. Contact your Nordson representative for help in ordering and installing upgrades. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 40 3-18 Installation Part 1603054-02 E 2015 Nordson Corporation...
  • Page 41: Troubleshooting

    Configuration section of the iControl Operator Interface manual for the shutdown procedure. NOTE: If the troubleshooting procedures in this section do not solve your problem, contact the Nordson Industrial Coating Systems Customer Support Center at (800) 433−9319 or your local Nordson representative. Error Codes and Alarm Messages...
  • Page 42 Preset out of range The preset sent to the remote device was out of range. Trigger ON message Remote device was commanded to trigger received − controller in while in lockout. lockout Continued... Part 1603054-02 E 2015 Nordson Corporation...
  • Page 43 Not implemented, future release Copy program failed to start* Not implemented, future release Compare program failed to Not implemented, future release start* Gun trigger error* Not implemented, future release Flow/pump trigger error* Not implemented, future release Continued... Part 1603054-02 E 2015 Nordson Corporation...
  • Page 44 The forward contactor did not engage. 4-17 1006 Reverse Contactor The reverse contactor did not engage. 4-17 1007 Forward End of Travel Limit The machine is at the forward end of travel 4-18 limit. Continued... Part 1603054-02 E 2015 Nordson Corporation...
  • Page 45 The remote Ethernet device did not respond 4-18 with a watchdog signal in 1 second. 3200 Reciprocator Watchdog fault The remote Ethernet device did not respond 4-26 with a watchdog signal in 1 second. Continued... Part 1603054-02 E 2015 Nordson Corporation...
  • Page 46: Can Network Errors

    CAN errors can also be caused by individual gun cards or the iControl PC to PC104 card interface. These errors do not indicate a specific device failure as all devices are in parallel on the CAN bus. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 47: Gun Card Troubleshooting

    If the fault changes to E7, check the resistance of the multiplier as described in the gun manual. If the fault code stays E8, check the continuity of the cable as described in the gun manual. Continued... Part 1603054-02 E 2015 Nordson Corporation...
  • Page 48 − The card was commanded to trigger but the system is locked message received out. Trigger ON commands will be ignored until the system is − controller in returned to the Run state. lockout Part 1603054-02 E 2015 Nordson Corporation...
  • Page 49: Gun Card Leds

    If the card has no power, make sure it is is applied to the board). properly seated in the backplane and the locking tab is working correctly. Replace the card if the other gun control cards have power. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 50 1. Reset switch (reboots the on-board 3. Status LED (green) 5. Foldback A LED (yellow) processor) 4. Foldback B LED (yellow) 6. Power LED (green) 2. Fault LED (red) 7. SW2 (2 position dipswitch for future use) Part 1603054-02 E 2015 Nordson Corporation...
  • Page 51: Hdlv Pump Troubleshooting

    Check for obstruction in pump air flow control valve. Clean valve as described in pump manifold manual. Pattern low PWM Pattern air flow less than commanded value. Check for obstruction in pattern air flow control valve. Clean valve as described in pump manifold manual. Continued... Part 1603054-02 E 2015 Nordson Corporation...
  • Page 52: Air Flow Re-Zero Procedure

    6. Press and hold the TEST button on each pump board until the red fault light turns on. Release the TEST button and wait for the red fault light to turn off. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 53 10. At the iControl console, check each gun control screen that was previously indicating air flow when the gun was off. No air flow should be indicated. Address Switch TEST Button Figure 4-2 Dual HDLV Pump Control Board Part 1603054-02 E 2015 Nordson Corporation...
  • Page 54: Ethernet Network Troubleshooting

    The ACT LED indicates network traffic when lit. The LNK LED to the right of the RJ45 connector indicates network status (green: 10Mb, amber: 100Mb, off: no connection). Replace the card if necessary, using only an identical or Nordson supplied replacement. If a single node fault is displayed: Check the electrical power to the remote node controller or coupler.
  • Page 55 4-15 Troubleshooting Error Message/Condition Correction Code TCP port already bound Programming error. Contact Nordson technical support. Listen failed Programming error. Contact Nordson technical support. File descriptors Programming error. Contact Nordson technical support. exceeded No permission to Programming error. Contact Nordson technical support.
  • Page 56: In/Out Positioner Troubleshooting

    If the gear reducer is not rotating but the motor is, replace the reducer. If the motor is not rotating, check the motor circuit protection, motor wiring, VFD, and motor control circuits. This fault must be reset from the iControl alarm screen. Continued... Part 1603054-02 E 2015 Nordson Corporation...
  • Page 57 Check all encoder mechanical and electrical connections. Make sure the encoder is powered. Check pulse output from the encoder. Replace encoder if necessary. This fault must be reset from the iControl alarm screen. Continued... Part 1603054-02 E 2015 Nordson Corporation...
  • Page 58 Communication with in/out positioner controller lost during color detected machine change cycle. lockout/watchdog fault Check the iControl alarm log for Watchdog or TCP/IP faults. Refer (Euro color change to Ethernet Network Troubleshooting on page 4-14. only) Part 1603054-02 E 2015 Nordson Corporation...
  • Page 59: Other In/Out Positioner Troubleshooting

    No corrective action is required unless the keyswitch Normal position does not allow motion. Refer to your system drawings for circuit details. If not Nordson USA ColorMax system: Apply jumper to force On the remote disable input. Refer to system drawings for jumper application.
  • Page 60 Ethernet network connections to the controller node, then replace the analog input module. In/Out Positioner preset set Normal operating scenario. Position change to Fixed. will only occur when a new part appears at the in/out positioner. Continued... Part 1603054-02 E 2015 Nordson Corporation...
  • Page 61 (home) and acquires a reverse reference value. This value is used to reset the in/out positioner position for Auto operations. Continued... Part 1603054-02 E 2015 Nordson Corporation...
  • Page 62 In/Out Positioner actual Incorrect encoder resolution NOTE: Encoder resolution can only be travel distance does not entered on in/out positioner entered or changed by a Nordson match value shown on configuration screen. representative. iControl screens. Verify encoder resolution (number of pulses...
  • Page 63: Reciprocator Troubleshooting

    If the gear reducer is not rotating but the motor is, replace the reducer. If the motor is not rotating, check the motor circuit protection, motor wiring, VFD, and motor control circuits. This fault must be reset from the iControl alarm screen. Continued... Part 1603054-02 E 2015 Nordson Corporation...
  • Page 64 Check all encoder mechanical and electrical connections. Make sure the encoder is powered. Check pulse output from the encoder. Replace the encoder if necessary. This fault must be reset from the iControl alarm screen. Continued... Part 1603054-02 E 2015 Nordson Corporation...
  • Page 65 Check the configured soft top and bottom limits. Make sure they do not allow travel to the limit sensors. Adjust the configured reciprocator Turn-Around Offset (Nordson CSR only) to ensure that the limit sensors are not engaged. Check reciprocator encoder wiring. If signals are switched the position tracking will be reversed.
  • Page 66: Other Reciprocator Troubleshooting

    Identify the fault and review the fault response to move troubleshooting information in this table. command. Controller configuration Contact Nordson technical support. incorrect. Configuration lockout applied Check the Reciprocator control screen for the to reciprocator. lockout indicator. Lockout is applied from the Configuration screens.
  • Page 67 No corrective action is required unless the keyswitch Normal position does not allow motion. Refer to your system drawings for circuit details. If not Nordson USA ColorMax system: Apply jumper to force On the remote disable input. Refer to system drawings for jumper application.
  • Page 68 Incorrect reciprocator VFD VFD parameters must be set to specified parameters. values in order to respond correctly to signals from reciprocator controller. Contact Nordson technical support. No reciprocator Refer to condition “No reciprocator response when Auto mode selected.” response when Auto mode selected.
  • Page 69: Other Fault Messages And Conditions

    Condition: iControl screen is Cycle console power. If condition persists, program card is locked up (no response) corrupted. Obtain and install another program card. Refer to Touch Screen Calibration when installing new program cards. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 70: Photoeye, Encoder, And Interlock Troubleshooting

    LEDs 1−20 are responding erratically, then check the I/O board inputs common voltage. For sinking inputs, +24 Vdc is applied to all HI terminals on the board as inputs common. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 71: Touch Screen Troubleshooting

    Failure to observe this warning could create a hazardous condition and could result in personal injury or property damage. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 72: No Touch Screen Display

    Open the console door and make sure the PC power switch is on. Have an electrician check these: Console fuses on the DIN rail, at the incoming power terminals. Unswitched power connections to the fuse blocks. Power supply to the console. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 73: Touch Screen Failure

    PC. Turn on power and use the numeric keys to enter values in selected data fields, or use the up and down arrow keys to change field values. Replace the keypad as soon as possible. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 74: Testing Ethernet Cables

    Check each connection. If you suspect a bad connection, you can pull the lead out of the module and punch it down again closer to the jacket. If the termination module connections are good, then the cable is faulty and must be replaced. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 75: Repair

    CAUTION: Do not turn off console power without first performing a program shutdown. Doing so could corrupt the iControl program and operating system on the program card. Refer to Program Shutdown in the Configuration section of the iControl Operator Interface manual for the shutdown procedure. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 76 Figure 5-3 Gun Control Card Replacement 1. Card cage (slot 1) 3. Gun 2 receptacle 5. Locking tab 2. Gun control card 4. Gun 1 receptacle 6. Backplane Part 1603054-02 E 2015 Nordson Corporation...
  • Page 77: Icontrol Pc Replacement

    1 on the board. Pin 1 is designated by a 1 printed on the I/O board and a square on the computer. 4. Complete the rest of the PC connections before powering up the iControl system. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 78: Ribbon Cable Connections

    Ribbon Cable Connections Connection Key Notch Pin 1 Mark (Arrow) PC End Conductor Pin 1 Ribbon Cable Connection Key Notch Pin 1 Mark (Arrow) I/O Board End I/O Board Figure 5-4 Computer−I/O Board Ribbon Cable Connections Part 1603054-02 E 2015 Nordson Corporation...
  • Page 79: Parts

    Parts Section 6 Parts Introduction For parts and technical support, call the Nordson Industrial Coating Systems Customer Support Center or contact your local Nordson representative. Customer Support Center Telephone: (800) 433−9319 Facsimile: (888) 229−4580 Email: finishing_csc@nordson.com Part 1603054-02 E 2015 Nordson Corporation...
  • Page 80: Console Part Number List

    Controller, iControl, Encore HD, 24 gun 1602188 Controller, iControl, Encore HD, 26 gun 1602189 Controller, iControl, Encore HD, 28 gun 1602190 Controller, iControl, Encore HD, 30 gun 1602191 Controller, iControl, Encore HD, 32 gun Part 1603054-02 E 2015 Nordson Corporation...
  • Page 81: Console Parts

    Console Parts Figures 6-5 through 6-8 show the replaceable parts for the iControl console. Contact your Nordson representative or the Customer Support Center for help in obtaining unlisted parts. Refer to Section 7 for electrical diagrams and junction box drawings.
  • Page 82 Parts Figure 6-5 Console Parts (1 of 4) (PC shown without cover) Part 1603054-02 E 2015 Nordson Corporation...
  • Page 83 FUSE, 3.15, fast-acting, 250V, 5x20 320586 RESISTOR, MF, 20K, 1W, 5 AXL 334805 FILTER, line, RFI, power, 10A Continued... 240V 240V 240V 240V 240V 240V 240V 240V Figure 6-6 Console Parts (2 of 4) Part 1603054-02 E 2015 Nordson Corporation...
  • Page 84 B: Use to prevent fault LED from lighting when odd number of guns are connected. Plug into gun card receptacle in place of receptacle harness for unused receptacle. One jumper is shipped with each console. AR: As Required Continued... Figure 6-7 Console Parts (3 of 4) Part 1603054-02 E 2015 Nordson Corporation...
  • Page 85 NOTE A: One receptacle is required for each automatic spray gun. B: Use to cap unused receptacles. One seal is shipped with each console. AR: As Required Figure 6-8 Console Parts (4 of 4) Part 1603054-02 E 2015 Nordson Corporation...
  • Page 86: Junction Boxes, Extension Boxes, And Control Panels

    Conveyor Encoder Part Description Note 1074261 ENCODER, 24 PPR, w/cable CAN Cable Part Description Note 1057592 JACKETED CABLE, twisted pair, shielded, 24 AWG, 120 ohm NOTE A: Order length desired in increments of one foot. Part 1603054-02 E 2015 Nordson Corporation...
  • Page 87: Photocells And Scanners

    SENSOR, light emitter, 72 in., 3/4 in. beam spacing, 96 beam 339752 SENSOR, light receiver, 72 in., 3/4 in. beam spacing, 96 beam NOTE A: Requires custom programming to match the application. Contact Nordson customer support. Photocell and Scanner Cables Part...
  • Page 88 6-10 Parts Part 1603054-02 E 2015 Nordson Corporation...
  • Page 89: Wiring Diagrams

    Wiring Diagrams Section 7 Wiring Diagrams Part 1603054-02 E 2015 Nordson Corporation...
  • Page 90 Wiring Diagrams Part 1603054-02 E 2015 Nordson Corporation...
  • Page 91 ___________________ Date: 09 Sept 2017 Vance Wilson Engineering Manager Industrial Coating Systems Amherst, Ohio, USA Nordson Authorized Representative in the EU Person authorized to compile the relevant technical documentation. Contact: Operations Manager Industrial Coating Systems Nordson Deutschland GmbH Heinrich-Hertz-StraBe 42-44...
  • Page 93 10011656 NOTICE THIS DRAWING IS NORDSON PROPERTY,CONTAINS PROPRIETARY INFORMATION AND MUST BE RETURNED UPON REQUEST. DO NOT CIRCULATE, REPRODUCE OR DIVULGE TO OTHER PARTIES WITHOUT WRITTEN CONSENT OF NORDSON. ENCORE HD iCONTROL THE FOLLOWING CONTROLLERS ARE SUITABLE FOR CLASS II, DIV 2, GROUP F &...

Table of Contents