4-2
Operation
Pump Control Panel Setup and Operation
Manifold and Pump Installation
1
Figure 4-1 Pump and Manifold Installation
1. Mounting screws (2)
2. Pump
Part 1605396-04
To install a pump and manifold into an existing pump panel:
1. See Figure 4-1. Make sure that the gaskets on the pump (2) and
manifold (5) are not damaged. If the gaskets are damaged, replace
them.
2. Set the manifold onto the appropriate mounting bracket (4) against the
pump panel wall (3). Secure the manifold with the mounting screws (6),
but do not tighten the screws.
3. Secure the pump to the pump panel and manifold using the pump
mounting screws (1). Tighten the pump mounting screws securely.
4. Tighten the manifold mounting screws securely.
5. Perform the Calibration procedure on page 4-7.
3
2
4
3. Pump panel wall
4. Manifold mounting bracket
5
6
5. Manifold
6. Manifold mounting screws (2)
E 2018 Nordson Corporation