4-4
Operation
Item
SW1
Node Address Switch
SW2
Console Address/Gun Type Switch
PB1
Test Mode Switch
(used for calibration)
PB2
Reset Switch
DS1
Power Indicator
DS2
Fault Indicator
Pin
1
+24 Vdc
2
+24 Vdc
3
+24 Vdc
4
+24 Vdc
5
+24 Vdc
6
+24 Vdc
7
+24 Vdc
8
Delivery 2 − Solenoid 6
9
Pressure 2 − Solenoid 5
10
Suction 2 − Solenoid 4
11
Suction 1 − Solenoid 3
12
Pressure 1 − Solenoid 2
13
Delivery 1 − Solenoid 1
14
Vacuum − Solenoid 7
Part 1605396-04