4-6
Operation
Figure 4-3 SW1 and SW2 Settings
Figure 4-4 CAN BUS TERM Jumper Settings
Part 1605396-04

Control Board Configuration

See Figure 4-3. Make sure that SW1 and SW2 are set as illustrated for the
Color-on-Demand system.
SW1
Position 1
For Color-on-Demand System:
1 OPEN
1
2
3
4
2 CLOSED
SW2
3 OPEN
OPEN
4 CLOSED
For Standard Manual Gun System:
1 OPEN
1
2
3
4
2 OPEN
SW2
3 OPEN
OPEN
4 CLOSED

Network Termination

See Figure 4-4. The control board is shipped with a jumper across pins 2
and 3 of the CAN BUS TERM terminals. Move the jumper to pins 1 and 2.
As Shipped Position
1
(for Prodigy Standard 2-Gun
W1
System)
CAN BUS TERM
Position for Prodigy
1
Color-on-Demand
1 or 2 Gun System
W1
CAN BUS TERM