Figure 4-15 Screen display for CURRENT suction line purge
Valve Counters
Figure 4-16 Valve Counter Screen
E 2018 Nordson Corporation
Use the Valve Counter screen for maintenance. The recommended valve
bladder change interval is 30,000 cycles. When this count is reached, you
should disassemble the color change manifolds and install new bladders.
Replacing the bladders before they fail will prevent color contamination and
expensive unscheduled downtime.
Note that the WARNING BLADDER MAINTENANCE message will appear
at the set count if enabled from the Service Screen. Refer to page 5-7 for
more information on this screen.
4-15