6.10 Horizontal trapezoid
Horizontal distortion is adjusted by the screws H1 and H2
Always turn one of the paired adjustment nuts clockwise while simultaneously turning the other
one counterclockwise!
Barco - OV-508/OV-513/OV-515– R5990099 – installation manual – revision 01– November 2007 ________________________________
Turn the adjustment screw H1 counterclockwise and
H2 clockwise until the vertical lines gets parallel to
the border of the screen
Turn the adjustment screw H1 clockwise and H2
counterclockwise until the vertical lines gets parallel
to the border of the screen.
________________________________________________
________________________________
________________________________
6. Optical adjustment
________________ 58