Wall Attachment; General; Rules - Barco OV-508 Installation Manual

Hide thumbs Also See for OV-508:
Table of Contents

Advertisement

7 Wall attachment

7.1 General

The wall fixation comprises some standard parts (brackets, screws) and some project
specific parts (profiles).
The wall fixation is available in a linear version and in an A-shape version.

7.2 Rules

The display wall has to be fixed to the floor, and in case of (more than) three rows, to the wall, too.
Fixation to the floor only:
In case a system has only to be fixed to the floor, every support is attached on the front side and on the back
side. These two anchoring devices are in a diagonal arrangement, see schematics:
Fixation to the floor and to the wall:
In case a system has to be fixed to the wall, too, the lower anchoring devices are only applied on the rear side.
For the upper anchoring devices (wall fixations), the following rules apply for each row which must be attached
to the wall:
The fixations are mounted on the inner side of the most left and the most right projection module, too. Within
the distance of these fixations, additional fixations are mounted in such a way that the distance between two
fixations does not exceed three projection modules, and that the fixations are equally distributed.
The following rows have to be fixed:
Entire height (number of rows)
3 or 4
5 or 6
Position of the lower and upper anchoring devices (schematics)
Lower anchor point (e.g. Chemical Anchor Upat UMV 60 M 10 when anchored to concrete)
Upper anchor point with wall (A connection has to be chosen that is designed for a maximal resulting traverse
force of F=1.0 kN in the dowel vertical and parallel to the Display Wall)
Upper anchor point Display Wall
30° - 60°
Barco - OV-508/OV-513/OV-515– R5990099 – installation manual – revision 01– November 2007 ________________________________
Fixation attached to row
3
2, 5
Example:
Since the display wall is attached to the wall,
the supports are attached to the floor on the
rear side only.
Wall fixations are attached on the inner side of
the most left/right projection module. Since
the max. allowed distance between two
fixations is 3 modules, one additional fixation
is required. This additional fixation is mounted
in a way that all fixations have the same
distance.
________________________________________________
________________________________
________________________________
7. Wall attachment
________________ 61
________________
________________

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ov-513Ov-515

Table of Contents