Supply Voltages; Handset; Junction Box - Codan NGT 2010 RF Technical & Service Manual

Transceiver system
Table of Contents

Advertisement

NGT—Technical description (2010)

Supply voltages

Handset

The supply voltages for the handset are shown in
Drawing
Table 18: Supply voltages for the Handset PCB in the handset
Supply
Standby
Handset power
+5 V
–9 V

Junction box

The supply voltages for the junction box are shown in
Drawing 04-03201, or
ALTERNATIVE TEXT
Drawing
Table 19: Supply voltages for the Audio PCB in the junction box (04-03201 or
04-03423)
Supply
A (protected)
+10 V
+5 V
+5 VQ
Drawing
Table 20: Supply voltages for the Microprocessor PCB in the junction box
Supply
+5 V
A (protected)
72
04-03125
Description
+5.4 V when transceiver is off ext from junction box
+9.2 V when transceiver is on ext from junction box
+5 V regulated supply
–9 V for IC7
04-03423
Description
Unregulated battery supply
+10 V regulated supply
+5 V regulated supply
+5 V quiet for opamp bias
04-03133
Description
+5 V digital supply
Unregulated battery supply
Table
18.
Source
IC10
IC5
Table 19
and
Table
Source
ext from RF unit
IC12
IC13
IC13 (filtered)
Source
IC13
from RF unit