NGT—Technical description (2010)

Second IF filter option

Drawing
NOTE
The second filter is fitted on a small daughter PCB (08-05890), which is fitted to the
main RF/IF PCB. When the filter is required, the relays K-1 and K-2 are switched by the
microprocessor IC408 and V207 to change the signal path to the second filter Z1.
The second filter may be either 500 Hz wide for CW and data applications
(15-10506-001) or it can be 2700 Hz wide for high-speed data applications
(15-10514-001).
The N (500 Hz) and W (2700 Hz) link on IC408 tell the processor which filter is fitted
so the synthesiser frequency is set correctly for the filter in use.
102
04-03379
and
04-03378 (sheet 2)
If the PCB issue status is -06 or earlier, see drawing
04-03378 (sheet
NGT Transceiver System Technical Service Manual
2).