3012—Overview and specifications
System requirements
HF SSB transceiver (data capable)
Maximum frequency offset error ±100 Hz (between transceivers)
Audio pass-band 500 to 2500 Hz ±1 dB
Power amplifier ALC—long time constant; peak limiting
Environmental
Operating environment
Operating temperature
Storage temperature
Relative humidity
Physical
Mechanical
Size
Weight
Sealing
Mounting
296
0 to 55°C
(32 to 131°F)
–40 to +60°C
(–40 to 140°F)
100%
210 mm W × 240 mm D × 65 mm H
(8.4 in W × 9.5 in D × 2.6 in H)
(includes allowance for rear connectors)
1.9 kg
(4.2 lb)
IP64
Free standing
Flange
Mobile mounting cradle
NGT Transceiver System Technical Service Manual