NGT—Technical description (2010)
Drawing
ALTERNATIVE TEXT
NOTE
Table 24: Supply voltages for the RF/IF PCB in the RF unit (04-03378)
Supply
A
+5 V
+26 V
+10 V
+10 VRx
+10 VTx
Drawing 04-03169, or
Drawing 04-03369, or
ALTERNATIVE TEXT
Drawing
Table 25: Supply voltages for the PA PCB and Filter and Control PCB in the RF
unit (04-03169 or 04-03369 or 04-03542)
Supply
A
+10 VA
+5 VA
+5 V
74
04-03378 (sheet 1)
If the PCB issue status is -06 or earlier, see drawing
Description
Unregulated battery supply
+5 V regulated supply
+26 V from charge pump
supply
+10 V regulated supply
+10 V In Rx
+10 V In Tx
04-03542
Description
Unregulated battery supply
+10 V regulated supply
+5 V regulated supply
+5 V regulated supply
04-03378 (sheet
Source
via Audio Interface PCB
IC210
IC402
via Audio Interface PCB
V415, V416
V417, V418
Source
ext
IC1
IC4
IC200
NGT Transceiver System Technical Service Manual
1).