Adjusting The Exciter Output Spurious Balance - Codan NGT 2010 RF Technical & Service Manual

Transceiver system
Table of Contents

Advertisement

NGT—Checks and adjustments

Adjusting the exciter output spurious balance

Drawing
ALTERNATIVE TEXT
NOTE
NOTE
Adjustment of the exciter output spurious balance may be necessary only if the mixer
IC102 on the RF/IF PCB in the RF unit has been replaced.
To perform the adjustment:
1
1
1
1
1
1
1
1
1
1
172
08-05261 (sheet 2)
If the PCB issue status is -06 or earlier, see drawing
The transceiver must be in Service mode to perform this check (see
page 154, Accessing Service
Select test channel 28.
Unplug the coaxial cable between the PA PCB and the RF/IF PCB in the RF unit.
Connect a spectrum analyser to the Tx test point on the RF/IF PCB.
Set up the spectrum analyser as follows:
Centre frequency
Frequency span
Vertical level
Trigger
Video bandwidth
Using the transceiver test unit, apply an audio signal of 1 kHz at a level of
300 mV p–p to:
the audio input on the 15-way GPIO connector on the junction box or 2012 RF
Unit (see
Figure 40 on page
the 2011 RF Unit via the NGT test handset (see
Hold down PTT.
Adjust the 24.9 MHz signal displayed on the spectrum analyser to the top of the
screen.
Reset the spectrum analyser centre frequency to 20.1 MHz.
Adjust R138 for a minimum 20.1 MHz signal.
The unwanted 20.1 MHz product should be greater that 60 dB below the 24.9 MHz
signal.
Release PTT.
or
08-05889 (sheet 2)
mode).
24.9 MHz
20 kHz
10 dB per division
Continuous sweep
1 kHz
170), or
NGT Transceiver System Technical Service Manual
08-05889 (sheet
Figure 41 on page
170)
2).