OPERATING PROCEDURES
When all the requirements for a brush-cleaning are met
and the 5 minutes expire, the screen will change to the
second screen, which is the standard POWER SWITCH
OFF screen. (See Figure 6-72.)
POWER SWITCH OFF
- = - = - = - = - = -
UNIT CLEANED
When the power switch is set in the ON position, the
System Mode of Operation screen is displayed. In this
example, the machine is ON but no mode of operation
has been selected. The second line of the display
indicates whether there is a sufficient supply of mix in the
hopper or if there is a MIX LOW or MIX OUT condition.
The third line of the display shows the temperature of the
mix hopper. After pressing the AUTO key, the last line of
the display shows the month and date 
(MM = month, DD = day) that the machine needs to be
disassembled and brush-cleaned.(See Figure 6-73.)
STANDBY
6
OUT
40.0F
BRUSH CLEAN ON:
Note: The MANUAL CLEAN LED will begin flashing
24 hours prior to a 14-day lockout. The four mode
LEDs will return to their normal function when the
machine is unlocked.
With the parts tray available for the shake side,
remove the following parts and place in the parts tray:
1. Remove the syrup lines from the syrup ports, and
remove the restrictor cap from the bottom of the door
spout.
2. Remove the spinner blade from the bottom of the
door spout by lifting up the locking collar on the
spinner coupling and pulling down the blade.
6-20
Figure 6-72
:MODE:
WSH-PMP
:MIX:
HOPPER
10/31
Figure 6-73
3. Remove the handscrews, freezer door, beater
assembly with driveshaft seal, and scraper blades
from the freezing cylinder.
4. Remove the driveshaft seal from the driveshaft of the
beater assembly.
5. Remove the freezer door O-ring, front bearing, pivot
pin, draw handle, and draw valve spinner assembly.
Remove the O-ring from the pivot pin.
6. Disassemble the draw valve spinner assembly.
Remove the driven spinner by grasping the draw
valve and pulling the driven spinner out. Remove the
spinner shaft seal.
7. Remove the two O-rings from the draw valve.
Note: To remove O-rings, use a clean, sanitized
towel to grasp the O-ring. Apply pressure upward
until the O-ring pops out of its groove. With the other
hand, push the top of the O-ring forward and it will roll
out of the groove and can easily be removed. If there
is more than one O-ring to be removed, always
remove the rear O-ring first. This will allow the O-ring
to slide over the forward O-rings without falling into
the open grooves.
8. From the pump cylinder, remove the retaining pin,
valve cap, piston, and the feed tube. Remove all 
O-rings and the check ring.
LOW
9. Remove the pump driveshaft from the drive hub in
40.0F
the rear wall of the mix hopper.
10. Remove the two small O-rings and one large O-ring
from the driveshaft.
Note: If the drip pans are filled with an excessive
amount of mix, it is an indication that the driveshaft
seal(s), or O-ring(s) should be replaced or properly
lubricated.