Figure 6-8
8. Assemble the draw-valve spinner assembly. Inspect
draw-valve O-rings for cuts or nicks. (Replace if cut
or nicked.) If draw-valve O-rings are in good
condition, slide the two O-rings into the grooves of
the draw valve and lubricate. (See Figure 6-9.)
Apply the appropriate
Taylor approved food safe lubricant.
Figure 6-9
9. Lubricate the outer diameter of the spinner shaft seal.
Fill the cups on each end of the seal with lubricant.
Insert the spinner shaft seal into the bottom of the
draw valve as far as it will go. The spinner shaft seal
should fit into the seal groove inside the draw valve
cavity.
Important! Inspect to see that the spinner shaft seal
is correctly installed in the groove. A worn, missing,
or improperly installed spinner shaft seal will cause
product leakage out the top of the draw valve. (See
Figure 6-10.)
Operating Procedures
23010
10. Lubricate the smaller end of the driven spinner. 
(See Figure 6-11.)
Apply the appropriate
Taylor approved food safe lubricant.
11. Squeezing the split end together, insert the driven
spinner through the metal opening of the draw valve
until it snaps into place. (See Figure 6-12.)
PH61 Peristaltic Pump
OPERATING PROCEDURES
Figure 6-10
Figure 6-11
Figure 6-12
11062
6
6-3