7.2.
Reassembly Instructions
7.2.1.
Attention when CF-19 series is repaired
• Please execute writing BIOS ID when you exchange the Main PCB.
• Parts (Sheet and rubber) etc. related various the Conductive Cloth and Heat Spreader cannot be recycled. Use new parts.
7.2.2.
Setting up the Inverter Ass'y and
LCD Unit
1. Set the LCD Unit Ass'y to LCD Front Cabinet/TS Panel
Ass'y.
2. Set the Digitizer Ass'y to the LCD Unit Ass'y.
3. Set the LED Thermal Diffusion Plate.
4. Fix the Digitizer Ass'y and LED Thermal Diffushion Plate
using the 4 Screws.<E36-15>
5. Attach the LED PCB Fix Sheet and LED PCB.
6. Connect the LED Cable to the Connector (CN100, D1.
L1, Speaker).
7. Connect the LED FPC to the Connector(D2).
8. Connect the TS FPC to the Connector(CN101).
9. Attach the PCB Edge Sheet and LED PCB INS Sheet
10. Attach the 2 PET Tapes.
LED PCB INS Sheet
PET Tape
PCB Edge Sheet
LED PCB
<E36-15>
:No.2
Connector
(CN101)
<E36-15>
:No.3
LED FPC
LCD Unit Ass'y
TS FPC
LCD Cable
PET Tape
Connector
(CN100)
LED PCB
Fix Sheet
<E36-15>:No.1
LED Thermal
Diffusion Plate
Digitizer
Ass'y
Connector(D1)
Connector(D2)
<E36-15>
:No.4
Connector(L1)
Connector
(Speaker)
LCD Front Cabinet/
TS Panel Ass'y
11. Attach the 3 Insulation Sheets.
12. Attach the LCD Conductive Tape and EMI Sheet.
Note:
Tighten the Screws in the numbered order (No1 to No4).
Screws <E36-15> : DRHM0157ZA
7-12
Insulation Sheet
LCD
Conductive Tape
EMI Sheet