Monitor Mode - Toshiba H9 Installation And Operation Manual

Toshiba adjustable speed drive installation and operation manual
Hide thumbs Also See for H9:
Table of Contents

Advertisement

Monitor Mode

The Monitor mode allows the user to monitor motor performance variables, control settings, and
configuration data during motor operation. There are 43 items that may be monitored from this mode. The
items are listed and described below.
Note:
The Monitor mode is a read-only mode. The settings cannot be changed from the
Monitor mode. For information on how to change the values, see the section titled
Default Setting Changes on pg.
Note:
Any two of the Underlined monitored items may be selected for display at the
Frequency Command screen while running via Program
Monitor
Note:
The
as A (Amps) or V (Voltage), or if the value is shown as a
rating.
Frequency at Trip — Display the at-trip frequency.
Frequency Reference — Displays the Frequency Setpoint (also called the Commanded
Frequency).
Output Current — Displays the Output Current as a percentage of the rated capacity of the H9
ASD.
DC Bus Voltage — Displays the Bus Voltage as a percentage of the rated capacity of the H9 ASD.
Output Voltage — Displays the Output Voltage as a percentage of the rated capacity of the H9
ASD.
AM Output — Displays the AM output terminal value for the function assigned to the AM terminal.
FM Output — Displays the FM output terminal value for the function assigned to the FM terminal.
Motor OL (Overload) Real — Displays the real-time Motor Overload value as a percentage of
the rated capacity of the motor.
Motor OL (Overload) Trip — Displays the Motor Overload Trip value as a percentage of the
rated capacity of the motor.
Motor Load — Displays the real-time Motor Load as a percentage of the rated capacity of the
motor.
ASD OL (Overload) Real — Displays the real-time ASD Overload as a percentage of the rated
capacity of the H9 ASD.
ASD OL (Overload) Trip — Displays the ASD Overload Trip value as a percentage of the rated
capacity of the ASD.
ASD Load — Displays the ASD Load as a percentage of the rated capacity of the H9 ASD.
Run Time — Displays the Cumulative Run Time in hours.
Compensation Frequency — Displays the Output Frequency after the application of the slip
compensation correction value (Post Compensation Frequency).
DBR OL (Overload) Real — Displays the real-time DBR Overload value as a percentage of the
Dynamic Braking Resistor capacity.
DBR OL (Overload) Trip — Displays the DBR Overload Trip value as a percentage of the
Dynamic Braking Resistor capacity.
DBR Load — Displays the DBR Load as a percentage of the Dynamic Braking Resistor capacity.
Feedback (inst) — Provides a status of the Real Time Feedback in Hz.
Feedback (1 second) — Provides a status of the 1-Second Averaging feedback in Hz.
H9 ASD Installation and Operation Manual
Selections.
F701
setting will determine if the Current and Voltage values displayed appear
74.
%
Utilities
Main
(percentage) of the ASD
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents