F528
Pattern Group 1 Selection 6
Program ⇒ Pattern Run ⇒ Speeds
This parameter allows the user to select 1 of 15 configured Preset Speeds as
the number 6 Selection to be included in Pattern Group 1.
Skip may be selected to ignore this Selection.
Setting
0 — Skip
1 – 15 Preset Speed Number
See
F523
for more information on this parameter.
Pattern Group 1 Selection 7
Program ⇒ Pattern Run ⇒ Speeds
This parameter allows the user to select 1 of 15 configured Preset Speeds as
the number 7 Selection to be included in Pattern Group 1.
Skip may be selected to ignore this Selection.
Setting
0 — Skip
1 – 15 Preset Speed Number
See
F523
for more information on this parameter.
Pattern Group 1 Selection 8
Program ⇒ Pattern Run ⇒ Speeds
This parameter allows the user to select 1 of 15 configured Preset Speeds as
the number 8 Selection to be included in Pattern Group 1.
Skip may be selected to ignore this Selection.
Setting
0 — Skip
1 – 15 Preset Speed Number
See
F523
for more information on this parameter.
Pattern 2 Repeat
Program ⇒ Pattern Run ⇒ Pattern Run
This parameter sets the number of times to repeat the Pattern Group 2.
174
Direct Access Number — F528
Parameter Type — Selection List
Factory Default — Skip
Changeable During Run — No
Direct Access Number — F529
Parameter Type — Selection List
Factory Default — Skip
Changeable During Run — No
Direct Access Number — F530
Parameter Type — Numerical
Factory Default — Skip
Changeable During Run — No
Direct Access Number — F531
Parameter Type — Numerical
Factory Default — 255 (Infinite)
Changeable During Run — No
Minimum — 1
Maximum — 255 (Infinite)
Units — Repetitions
H9 ASD Installation and Operation Manual