F743
Trace Data 2
Program ⇒ Utilities ⇒ Trace
This parameter is used to select the Trace Data 2 item from
to be read and stored in accordance with the setup of parameters
F741.
See
F740
for more information on this parameter setting.
Trace Data 3
Program ⇒ Utilities ⇒ Trace
This parameter is used to select the Trace Data 3 item from
to be read and stored in accordance with the setup of parameters
F741.
See
F740
for more information on this parameter setting.
Trace Data 4
Program ⇒ Utilities ⇒ Trace
This parameter is used to select the Trace Data 4 item from
to be read and stored in accordance with the setup of parameters
F741.
See
F740
for more information on this parameter setting.
Baud Rate (RS485 2-wire)
Program ⇒ Communications ⇒ Communication Settings
This parameter plays a role in the setup of the communications network by
establishing the Baud Rate of the communications link.
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.
Settings:
0 — 9600
1 — 19200
2 — 38400
Parity (RS485 2- and 4-wire)
Program ⇒ Communications ⇒ Communication Settings
This parameter plays a role in the setup of the communications network by
establishing the Parity setting of the communications link.
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.
Settings:
0 — No Parity
1 — Even Parity
2 — Odd Parity
204
Direct Access Number — F743
Parameter Type — Selection List
Factory Default — Freq. Reference
Table 9 on pg. 242
Changeable During Run — Yes
F740
and
Direct Access Number — F744
Parameter Type — Selection List
Factory Default — Output Current
Table 9 on pg. 242
Changeable During Run — Yes
F740
and
Direct Access Number — F745
Parameter Type — Selection List
Factory Default — DC Voltage
Table 9 on pg. 242
Changeable During Run — Yes
F740
and
Direct Access Number — F800
Parameter Type — Selection List
Factory Default — 19200
Changeable During Run — Yes
Units — bps
Direct Access Number — F801
Parameter Type — Selection List
Factory Default — Even Parity
Changeable During Run — Yes
H9 ASD Installation and Operation Manual