Emc And Environmental Type Tests - Siemens RUGGEDCOM RSG910C Installation Manual

Simatic net rugged ethernet switches
Hide thumbs Also See for RUGGEDCOM RSG910C:
Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RSG910C has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
61000-4-2
61000-4-3
61000-4-4
61000-4-5
61000-4-6
61000-4-8
36
EN50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity
of the Signaling and Telecommunications Apparatus
EN50121-3-2
Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus
EN 50155
Railway applications – Rolling stock – Electronic equipment
Test
IEC
ESD
IEC
Radiated RFI
IEC
Burst (Fast Transient)
IEC
Surge
IEC
Induced (Conducted) RFI
IEC
Magnetic Field
Description
Enclosure
Contact
Enclosure Air
Enclo-
sure Ports
Signal Ports
DC Pow-
er Ports
AC Pow-
er Ports
Earth
Ground Ports
Signal Ports
DC Pow-
er Ports
AC Pow-
er Ports
Signal Ports
DC Pow-
er Ports
AC Pow-
er Ports
Earth
Ground Ports
Enclo-
sure Ports
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
10 V
10 V
10 V
10 V
100 A/m Continuous
1000 A/m for 1 s
Installation Manual, 02/2020, C79000-G8976-1405-06
Severi-
ty Levels
4
4
4
4
4
4
4
3
4
3
3
3
3
 
RUGGEDCOM RSG910C

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RUGGEDCOM RSG910C and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents