Download Print this page

Copper Ethernet Port Specifications; Operating Environment - Siemens RUGGEDCOM RSG910C Installation Manual

Simatic net rugged ethernet switches
Hide thumbs

Advertisement

Table of Contents
Standard
1588-2008
62439-2:2016
62439-3:2016
5.4

Copper Ethernet Port Specifications

The following details the specifications for copper Ethernet ports that can be ordered
with the RUGGEDCOM RSG910C.
Speed
Connector
Duplex
Cable Type
Wiring Standard
Maximum Distance
Isolation
a
Auto-negotiating.
b
Shielded.
c
Auto-crossover and auto-polarity.
d
Typical distance. Dependent on the number of connectors and splices.
e
RMS 1 minute.
5.5

Operating Environment

The RUGGEDCOM RSG910C is rated to operate under the following environmental
conditions.
Ambient Operating Tempera-
ture
Ambient Storage Temperature
Ambient Relative Humidity
Maximum Altitude
a
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
b
Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM
SFP Transceivers Catalog for SFP temperature ratings.
c
Non-condensing.
RUGGEDCOM RSG910C
Installation Manual, 02/2020, C79000-G8976-1405-06
10 Mbps Ports
IEEE
ü
IEC
 
IEC
ü
a
10/100/1000Base-TX
RJ45
a
FDX/HDX
b
> CAT 5
c
TIA/EIA T568A/B
d
100 m (328 ft)
e
1.5 kV
a b
c
5.4 Copper Ethernet Port Specifications
100 Mbps
1000 Mbps
Ports
Ports
ü
ü
ü
ü
ü
ü
-40 to 85 °C (-40 to 185 °F)
-40 to 85 °C (-40 to 185 °F)
5% to 95%
2000 m (6562 ft)
Technical Specifications
Description
Precision Time Protocol (PTP)
Version 2
Media Redundancy Protocol
(MRP)
High-Availability Seamless Re-
dundancy (HSR), Parallel Redun-
dancy Protocol (PRP)
27

Advertisement

Table of Contents
loading

  Also See for Siemens RUGGEDCOM RSG910C

  Related Content for Siemens RUGGEDCOM RSG910C

This manual is also suitable for:

Simatic net ruggedcom rsg907rRuggedcom rsg909r