Page 2
Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet switches RUGGEDCOM RSG920P Communication Ports Technical Specifications Equipment Manual Certification 10/2023 C79000-G8976-1172-09...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer's exposure to cyber threats.
SIMATIC NET glossary The SIMATIC NET glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Registered trademarks The following and possibly other names not identified by the registered trademark sign ®...
Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile app Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
Introduction The RUGGEDCOM RSG920P is a rugged, high density, Ethernet switch designed to operate in harsh environments with widely varying climatic and environmental conditions. Tested and certified to withstand extreme temperatures, vibrations and shocks, the RUGGEDCOM RSG920P offers exceptional reliability for industrial applications, such as transportation systems and oil/gas applications.
Introduction 1.2 Description Rated for Reliability in Harsh Environments • Immunity to EMI and heavy electrical surges • -40 to 85 °C (-40 to 185 °F) operating temperature (no fans) • Conformal coated printed circuit boards (optional) Universal Power Supply Options •...
Introduction 1.3 Required Tools and Materials Main Power Supply Terminal Block Figure 1.1 RUGGEDCOM RSG920P RS-232 Console Port The serial console port is for interfacing directly with the device and accessing initial management functions. For information about connecting to the device via the serial console port, refer to "Connecting to the Device"...
WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment. Do not dispose of devices at public disposal sites. For environmentally friendly recycling and the disposal of devices, contact a certified disposal company for electronic scrap or your Siemens contact. For more information, refer to https://support.industry.siemens.com/cs/ww/en/ view/109479891.
Page 14
Introduction 1.5 Cabling Recommendations reliable, error-free data communication, new and pre-existing communication paths should be verified for TIA/EIA-568-A compliance. The following table summarizes the relevant cabling standards: Cabling 1000Base- Required Action Category TX Compliant < 5 New wiring infrastructure required. Verify TIA/EIA-568-A compliance. No action required.
Installing the Device This chapter describes how to install the device, including mounting the device, connecting power, and connecting the device to the network. DANGER Electrocution hazard – risk of serious personal injury and/or damage to equipment Before performing any maintenance tasks, make sure all power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RSG920P is designed for maximum mounting and display flexibility.
Installing the Device 2.3.1 Mounting the Device on a DIN Rail 2.3.1 Mounting the Device on a DIN Rail The RUGGEDCOM RSG920P can be ordered with a DIN rail adapter preinstalled on the back of the chassis. Use the adapter to mount the device to a standard 35 mm (1.4 in)IEC/EN 60715 or TS35 DIN rail.
Installing the Device 2.3.2 Mounting the Device to a Panel Panel/DIN Rail Adaptor Figure 2.2 Mounting the Device to a DIN Rail Insert a flathead screwdriver into the slot of the sliding release and move it down. Push the device against the bottom of the DIN rail, then let go of the sliding release to latch the device.
Page 21
Installing the Device 2.3.2 Mounting the Device to a Panel Rear Mount Orientation Front Mount Orientation Side Mount Orientation Figure 2.4 Panel Mount Options To mount the device to a panel, do the following: Secure the adapters to the device in the desired orientation. Place the device against (side or rear mount orientation) or insert it into (front mount orientation) the panel and align the adapters with the mounting holes.
Installing the Device 2.4 Grounding the Device Grounding the Device The RUGGEDCOM RSG920P chassis features a threaded hole for connecting the device to ground (Protective Earth). It is recommended to terminate the ground connection with an #8 ring tongue or spade lug, and then torque to 1.2 N·m (11 lbf- in).
Installing the Device 2.6 Connecting the Digital Inputs Failsafe Alarm Relay Terminal Normally Open Terminal Common Terminal Normally Closed Terminal Figure 2.7 Failsafe Alarm Relay Wiring Connecting the Digital Inputs The RUGGEDCOM RSG920P offers two independent digital inputs for monitoring external equipment. Each digital input is associated with an alarm that is configured in RUGGEDCOM RSG920P.
Installing the Device 2.7 Connecting Power Note For technical specifications related to the digital input ports, refer to "Digital Input Specifications" (Page 32). To connect a digital input, do the following: Secure a European-style terminal block (or Euroblock) to the terminal. Connect the positive cable to the DI1/2+ terminal.
Installing the Device 2.7.1 Connecting High AC/DC Power • Use minimum #16 gage copper wiring when connecting terminal blocks 2.7.1 Connecting High AC/DC Power To connect a high AC/DC power supply to the device, do the following: NOTICE Electrical hazard – risk of damage to equipment Do not connect AC power cables to terminals for DC power.
Installing the Device 2.7.2 Connecting Low DC Power 2.7.2 Connecting Low DC Power To connect a single or dual power sources to the low DC power supply, do the following: NOTICE When connecting two external power sources, if the first external power source has a voltage lower than 33 VDC, the second power source must have a voltage lower than 33 VDC as well.
For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m (118 in). Otherwise, Siemens recommends using the RUGGEDCOM RPS1300 switch-mode AC power supply. For more information about this power supply, refer to https:// support.industry.siemens.com/cs/ww/en/view/109478699.
Page 28
Installing the Device 2.7.3 Connecting External PoE Power To support the IEEE 802.3af specification (15 W/port output), the external power supply must meet the following requirements: Power Input Range Isolation Minimum Supply Type Power Required Minimum Maximum 45 VDC 57 VDC 1.5 kVAC/2.2 kVDC 75 W To connect an external power supply for the PoE ports, do the following:...
Page 29
Installing the Device 2.7.3 Connecting External PoE Power RUGGEDCOM RSG920P Equipment Manual, 10/2023, C79000-G8976-1172-09...
Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RSG920P console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM ROS Configuration Manual" for the RUGGEDCOM RSG920P.
Page 31
Device Management 3.1 Connecting to the Device RJ45 Console Port USB Type-B Console Port Access Plate Figure 3.1 Console Ports Connection to the RJ45 console port is made using an RJ45-to-DB9 console cable. The following is the pin-out for the RJ45 console port: Figure 3.2 RJ45 Console Port Pin Configuration Name...
Device Management 3.2 Configuring the Device Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RSG920P console and Web interfaces via the device's IP address. For more information about available ports, refer to "Communication Ports"...
Page 33
Device Management 3.3 Inserting/Removing the MicroSD Card MicroSD Card Access Plate Figure 3.3 Inserting/Removing a MicroSD Card When removing the card, first press the card in until it springs back. Without touching the contacts on the card, insert or remove the microSD card. When installing the card, push the card in until it clicks in place.
Communication Ports The RUGGEDCOM RSG920P can be equipped with various types of communication ports to enhance its abilities and performance. SFP Transceiver Sockets Copper Ethernet Ports PoE+ Ports Figure 4.1 Port Assignment Port Type 1 to 16 10/100/1000 Mbps Copper Ethernet Ports 13 to 16 10/100/1000 Mbps Power-over-Ethernet (POE) Ports 17 to 20...
Page 35
Communication Ports 4.1 Copper Ethernet Ports WARNING Electric shock hazard – risk of serious personal injury and/or equipment interference If shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more importantly, create a potential shock hazard that can result in serious injury.
"RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309]". Note Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. RUGGEDCOM RSG920P...
Communication Ports 4.3 PoE Ports PoE Ports The RUGGEDCOM RSG920P supports four Power over Ethernet (POE) ports (ports 13 to 16) powered by an external power supply. Each port complies with the IEEE 802.3at standard. The total allowable power budget for all ports is 120 W. If the external power supply is less than 120 W, to prevent exceeding the power budget, port priorities can be set via the RUGGEDCOM ROS operating system to disable low priority ports when demand is too high.
Page 38
Communication Ports 4.3 PoE Ports Figure 4.5 PoE Port Pin Configuration Name PoE Voltage 54 V Nominal Description 10/100Base-TX 1000Base-TX Ports 13 and 15 Ports 14 and 16 BI_DB+ Receive Data+ or Bi-Directional BI_DB- Receive Data- or Bi-Directional BI_DA+ Transmit Data+ or Bi-Directional Reserved (Do...
Technical Specifications This section details the specifications and operating conditions of the device. General specifications Insulation Class I Overvoltage category OVC II Power Supply Specifications Power Input Range Internal Isolation Maximum Supply Type Fuse Rating Power Minimum Maximum Consumption 88 VDC 300 VDC 3.15 A(T) 2.8 kVAC...
Technical Specifications 5.5 Copper Ethernet Port Specifications Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM RSG920P. Speed Interface Connector Duplex Cable Type Wiring Maximum Isolation (Mbps) Standard Distance 10/100/1000 RJ45 FDX/HDX >...
Information Technology Equipment – Safety – Part 1: General Requirements) 6.1.3 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: RUGGEDCOM RSG920P Equipment Manual, 10/2023, C79000-G8976-1172-09...
Certification 6.1.4 FCC • EN 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements • EN 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments • EN 60825-1 Safety of Laser Products – Equipment Classification and Requirements •...
Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.6 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.7...
Certification 6.1.9 ACMA MSIP-REM-S14-RSG920P A copy of the KC Declaration of Conformity is available from Siemens Canada Ltd.. For contact information, refer to "Contacting Siemens" (Page viii). Notices specific to the RRA: WARNING Class A Equipment (Industrial Broadcasting and Communication Equipment) This device complies with the limits of a Class A electromagnetic wave device and is intended for use outside of a residential environment.
Certification 6.1.10 RoHS 6.1.10 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: • EU RoHS Directives (EU) 2011/65 and (EU) 2015/863 European Directive for Restriction of Hazardous Substances •...
Page 51
Certification 6.2 EMC and Environmental Type Tests EMC Type Tests per IEC 61850-3 Test Description Test Levels Severity Levels Electrostatic Enclosure ±8 kV 61000-4-2 Discharge (ESD) Contact Enclosure Air ±15 kV Radiated Radio Frequency Enclosure 20 V/m 61000-4-3 Immunity (RFI) Ports Burst (Electrical Signal Ports ±4 kV at 2.5 kHz...
Page 52
AC Power 5 kV Ports Severity level set by Siemens. Common mode tests performed on the signal port shield. For IEC 61850-3 compliance when using Power-over-Ethernet (PoE), an IEC 61850-3 compliant PoE power supply must be installed in the vicinity of the device with power cabling no longer than 3 meters (118 in).
Page 53
Certification 6.2 EMC and Environmental Type Tests Description Test Levels Severity Levels Earth ±4 kV Ground Ports Damped Oscillatory Wave Signal Ports 2.5 kV Common Mode at 1 MHz DC Power Port 2.5 kV Common and Differential Mode at 1 MHz AC Power Port 2.5 kV Common and Differential Mode at 1 MHz...