  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RSG907R Edition 02/2021 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RSG907R Communication Ports Technical Specifications Installation Manual Certification 02/2021 C79000-G8976-1387-12...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................v Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................2 Description ......................2 Required Tools and Materials ................. 4 Decommissioning and Disposal ................4 Installing the Device ......................
  • Page 5 Table of Contents Failsafe Alarm Relay Specifications ..............32 Supported Networking Standards ................ 32 Fiber Optic Ethernet Port Specifications ............... 33 Operating Environment ..................33 Mechanical Specifications ..................34 Dimension Drawings ................... 34 Certification ......................... 37 Approvals ......................37 6.1.1 CSA ........................
  • Page 6: Preface

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Contacting Siemens

    FAQs and manuals • Submit SRs or check on the status of an existing SR • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
  • Page 10: Introduction

    Ports designated for Redundant Network Access (RNA) – ports A/B and 5 – can be customized with a wide array of Small Form-factor Portable (SFP) transceivers offered by Siemens, making the device flexible to the needs of the redundant network application.
  • Page 11: Feature Highlights

    Introduction 1.1 Feature Highlights Feature Highlights Ethernet Ports • 4 x 100Base-FX fiber optic Ethernet ports • 3 x 1000Base-SX/LX SFP transceivers • Industry standard LC fiber optical connectors Rated for Reliability in Harsh Environments • Immunity to EMI and heavy electrical surges •...
  • Page 12 Introduction 1.2 Description POWER LED ALARM LED USB Console Port RNA Port (Port A/B) Port 5 Fiber Optic Ethernet Ports (Ports 1 to 4) Failsafe Alarm Relay Power Supply Terminal Blocks Chassis Ground Screw Figure 1.1 RUGGEDCOM RSG907R POWER LED Illuminates green during boot up and when power is supplied to the device.
  • Page 13: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RSG907R: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device. USB Type-B console port cable For connecting to the RUGGEDCOM ROS console interface.
  • Page 14: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 15: Unpacking The Device

    Visually inspect each item in the package for any physical damage. Verify all items are included. IMPORTANT If any item is missing or damaged, contact Siemens for assistance. Installing the Device in Hazardous Locations The RUGGEDCOM RSG907R is designed to comply with the safety standards for Class I, Division 2, Zone 2 hazardous locations where concentrations of flammable gases, vapors or liquids may be present, as opposed to normal operating environments.
  • Page 16 Installing the Device 2.3 Installing the Device in Hazardous Locations Special Conditions for Safe Use Installation and use of the device in a hazardous location must meet the following special conditions for safe use: • The equipment shall be installed in an enclosure that is considered to be not accessible in normal operation without the use of a tool providing a degree of protection of not less than IP54 according to IEC 60079-0 and IEC 60079-7 or IEC 60079-15.
  • Page 17: Mounting The Device

    Installing the Device 2.4 Mounting the Device Sample Hazardous Location Label The following is an example of the RUGGEDCOM RSG907R hazardous location label: Figure 2.1 Compliance Label (Example) Mounting the Device The RUGGEDCOM RSG907R is designed for maximum mounting and display flexibility. It can be equipped with adapters that allow it to be attached to a DIN rail or panel.
  • Page 18 Installing the Device 2.4.1 Mounting the Device on a DIN Rail Mounting the Device To mount the device to a DIN rail, do the following: Hook the top teeth of the adapter onto the DIN rail. Note The adapter features a sliding release with a slot at the bottom for a flathead screwdriver.
  • Page 19: 2.4.2 Mounting The Device To A Panel

    Installing the Device 2.4.2 Mounting the Device to a Panel Removing the Device To remove the device from a DIN rail, do the following: Insert a flathead screwdriver into the slot of the sliding release and move it down. DIN Rail DIN Rail Adapter Figure 2.3 Removing the Device from a DIN Rail...
  • Page 20 Installing the Device 2.4.2 Mounting the Device to a Panel To mount the device to a panel, do the following: Secure the mounting adapters to the top and bottom of the device using the four M4 screws included with the device. Screw (M4) Panel Mount Adapter Figure 2.4...
  • Page 21: Connecting The Failsafe Alarm Relay

    Installing the Device 2.5 Connecting the Failsafe Alarm Relay Place the device against the panel and align the adapters with the mounting holes. Screw (M5 or #10-24) Panel Mount Adapter Figure 2.5 Panel Mounting Secure the adapters to the panel with M5 or #10-24 screws. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
  • Page 22 Installing the Device 2.5 Connecting the Failsafe Alarm Relay To connect the failsafe alarm relay, do the following: Insert the failsafe alarm relay terminal block into the device and tighten the screws. Figure 2.6 Assembling the Failsafe Alarm Relay Terminal Block Connect a failsafe device to the terminal block. Failsafe Alarm Relay Terminal Block Normally Open Common...
  • Page 23: Connecting Power

    Installing the Device 2.6 Connecting Power Connecting Power The RUGGEDCOM RSG907R features two input terminals that allow the device to be powered by: • Up to one independent AC and one independent DC power source • Two independent DC power sources NOTICE Electrical hazard –...
  • Page 24 Installing the Device 2.6.1 Connecting AC or DC Power • Make sure a terminal block is installed in the unused port and that any wires from the secondary terminal block are properly terminated • Make sure the first power source is off before connecting (or disconnecting) a second power source If connecting a secondary power source, make sure the power source currently connected to the device is disabled (e.g.
  • Page 25: 2.6.2 Wiring Examples

    Installing the Device 2.6.2 Wiring Examples Connect the ground wire to the 5 POS Terminal Block Chassis/Ground Terminal chassis/ground terminal on the Negative Terminal terminal block. Positive Terminal LO DC Power supply Figure 2.9 Terminal Block Wiring Connect the Positive wire to the positive (+) terminal on the terminal block.
  • Page 26 Installing the Device 2.6.2 Wiring Examples HI Power Supply Configurations   Figure 2.11 Single HI AC Power Input Figure 2.12 Single HI DC Power Input Configuration Configuration RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
  • Page 27 Installing the Device 2.6.2 Wiring Examples   Figure 2.13 Dual HI AC and DC Power Figure 2.14 Dual HI DC Power Supplies Supplies RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
  • Page 28: Connecting The Device To The Network

    Installing the Device 2.7 Connecting the Device to the Network LO Power Supply Configurations   Figure 2.15 Single LO DC Power Input Figure 2.16 Dual LO DC Power Input Configuration Configuration Connecting the Device to the Network Steps to connect the device to the network are application-specific. RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
  • Page 29 Installing the Device 2.7 Connecting the Device to the Network Connecting to a Local Area Network In this application, the device operates as a switch on a Local Area Network (LAN). Connect the device as follows:   Port Connect To... Not used Not used 5 (Coupler) Connect to an...
  • Page 30 Installing the Device 2.7 Connecting the Device to the Network DAN (RUGGEDCOM RSG907R RSG907R) Figure 2.18 A PRP Network Connecting to an HSR Ring In this application, the device operates as an HSR RedBox in an HSR ring. Connect the device as follows:  ...
  • Page 31 Installing the Device 2.7 Connecting the Device to the Network Connecting an HSR Ring and PRP Network In this application, the device operates as one of two HSR/PRP RedBoxes in an HSR ring that is connected to either LAN A or LAN B in the PRP network. Connect the device as follows:  ...
  • Page 32 Installing the Device 2.7 Connecting the Device to the Network   Port Connect To... Connect to port B of the neighboring HSR/HSR RedBox or to the HSR ring Connect to port A of the neighboring HSR/HSR RedBox or to the HSR ring 5 (Coupler) Connect to the coupling...
  • Page 33 Installing the Device 2.7 Connecting the Device to the Network RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
  • Page 34: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RSG907R console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM RSG907R. IMPORTANT Ethernet cables should be only be connected/disconnected in a non-hazardous area, or when the device is not energized.
  • Page 35: Configuring The Device

    Device Management 3.2 Configuring the Device Ethernet Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RSG907R console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RSG907R is https://192.168.0.1.
  • Page 36: Communication Ports

    Communication Ports The RUGGEDCOM RSG907R can be equipped with various types of communication ports to enhance its abilities and performance. Ports A and B Port 5 Ports 1 to 4 Figure 4.1 Port Assignment Port Type SFP Transceiver (1000Base-SX/LX) SFP Transceivers (1000Base-SX/LX) 1 to 4 Fiber Optic (100Base-FX) Ethernet Ports Redundant Network Access (RNA) Ports...
  • Page 37 RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309]. IMPORTANT Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. IMPORTANT RNA ports A and B must operate at the same speed.
  • Page 38: Fiber Optic Ethernet Ports

    SFP Transceivers The RUGGEDCOM RSG907R supports up to three Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. LEDs Each socket features an LED that indicates its link state. State...
  • Page 39 RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309]. IMPORTANT Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. RUGGEDCOM RSG907R...
  • Page 40: Technical Specifications

    Technical Specifications This section provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the minimum input voltage for the power supply is provided at the power source. Hazardous Environments Power Input Voltage Internal Isolation Maximum...
  • Page 41: Failsafe Alarm Relay Specifications

    Technical Specifications 5.2 Failsafe Alarm Relay Specifications Failsafe Alarm Relay Specifications Hazardous Environments Maximum Switching Voltage Rated Isolation Switching Current 30 VDC 1500 V for 1 minute 80 VDC 0.3 A 30 VAC 30 VDC 5.0 kVAC between coil and contacts 1.0 kVAC between contacts 250 VAC...
  • Page 42: Fiber Optic Ethernet Port Specifications

    3 dBm. To convert from peak to average, subtract 3 dBm. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. Data...
  • Page 43: Mechanical Specifications

    Technical Specifications 5.6 Mechanical Specifications Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings. Non-condensing. Mechanical Specifications Weight 2.4 kg (5.3 lbs) Ingress Protection IP40 Enclosure Die Cast Aluminum Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated.
  • Page 44 Technical Specifications 5.7 Dimension Drawings 38.1 163.12 Figure 5.2 Panel Mount Dimensions 162.72 Figure 5.3 DIN Rail Mount Dimensions RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
  • Page 45 Technical Specifications 5.7 Dimension Drawings RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
  • Page 46: Certification

    Certification The RUGGEDCOM RSG907R device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. Approvals This section details the standards to which the RUGGEDCOM RSG907R complies. 6.1.1 This device meets the requirements of the following Canadian and U.S. standards under certificate CSA 18CA70171440: •...
  • Page 47: 6.1.2 Csa/Sira

    Certification 6.1.2 CSA/Sira • ANSI/UL 60079-15:13 Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Type of Protection "n" The device is marked with a CSA symbol that indicates compliance with both Canadian and U.S. requirements. It is specifically approved for use in Division 2 and Zone 2 hazardous locations with the following markings: •...
  • Page 48: European Union (Eu)

    Electromagnetic compatibility of multimedia equipment – Emission requirements The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 49: 6.1.5 Fda/Cdrh

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.6 ISED This device is declared by Siemens AG to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.7...
  • Page 50: Rra

    Republic of Korea (South Korea) as a Class A product in a commercial, industrial or business environment. R-REM-S14-RSG907R A copy of the KC Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 51: Emc And Environmental Type Tests

    Certification 6.2 EMC and Environmental Type Tests • EN50121-4 Railway applications – Electromagnetic Compatibility – Emission and Immunity of the Signaling and Telecommunications Apparatus • EN50121-3-2 Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus • EN 50155 Railway applications – Rolling stock – Electronic equipment EMC and Environmental Type Tests The RUGGEDCOM RSG907R has passed the following Electromagnetic Compatibility (EMC) and environmental tests.
  • Page 52 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels Pulse Magnetic Field Enclosure 300 A/m 61000-4-9 Ports Voltage Dips and Interrupts AC Power 30% for 0.5 Cycles   61000-4-11 Ports 60% for 5 Cycles 100% for 250 Cycles Mains Frequency Voltage Signal Ports 30 V Continuous...
  • Page 53 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels IEEE 1613 Oscillatory Signal Ports 2.5 kV Common Mode @ 1 MHz DC Power Ports 2.5 kV Common Mode @ 1 MHz 1 kV Differential Mode @ 1 MHz IEEE 1613 HV Impulse Signal Ports 5 kV (Failsafe Relay)
  • Page 54 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

This manual is also suitable for:

Ruggedcom rsg907r

Table of Contents