Faults and alarms
Cause:
Configuration error of the Technology Extension RAILCTRL. The value range of one or several coordinates of the
configured geometry is exceeded.
In this state, the RAILCTRL Technology Extension is not ready for operation, and can only be activated once the cause has
been resolved.
Fault cause:
1 (= 01 hex):
The start of the primary section exceeds the valid value range (p30461).
2 (= 02 hex):
The length of the primary section exceeds the valid value range (p30463).
3 (= 03 hex):
The length of the secondary section exceeds the valid value range (p30464).
4 (= 04 hex):
The position offset of the secondary section exceeds the valid value range (p30465).
5 (= 05 hex):
The hysteresis exceeds the valid value range (p30466).
6 (= 06 hex):
The offset of the master/slave transition exceeds the valid value range (p30467).
7 (= 07 hex):
The calculation for the end of the primary section exceeds the valid value range (p30461, p30463).
8 (= 08 hex):
The conversion for the start of the primary section in its own coordinates exceeds the valid value range.
9 (= 09 hex):
The conversion for the end of the primary section in its own coordinates exceeds the valid value range.
10 (= 0A hex):
The conversion of the geometry of the previous segment in its own coordinate system exceeds the valid value range.
11 (= 0B hex):
The conversion of the geometry of the subsequent segment in its own coordinate system exceeds the valid value range.
12 (= 0C hex):
The conversion of its own geometry in the coordinate system of the previous segment exceeds the valid value range.
13 (= 0D hex):
The conversion of its own geometry in the coordinate system of the subsequent segment exceeds the valid value range.
84
Function Manual, 09/2019, A5E38120767B