Siemens SINAMICS RAILCTRL Function Manual page 56

Rail control
Table of Contents

Advertisement

Commissioning
6.6 Examples for configuring RAILCTRL
Parameter Setting
RAILCTRL parameters to the previous segment SERVO_02
p30452[0]
r30451 (from
SERVO_02)
p30490[0]
999
p30492[0]
0
RAILCTRL parameters to the subsequent segment (no following Control Unit)
p30452[1]
0
p30490[1]
999
p30492[1]
0
54
Description
RAILCTRL adjacent segment assignment input, previous segment interconnected with
RAILCTRL adjacent segment assignment output from the previous segment
RAILCTRL CU communication activation, previous segment: no communication via DRIVE-CLiQ
RAILCTRL coordinate offset DRIVE-CLiQ setting, previous segment
RAILCTRL adjacent segment assignment input, subsequent segment
RAILCTRL CU communication activation, subsequent segment: no communication via DRIVE-
CLiQ
RAILCTRL coordinate offset DRIVE-CLiQ setting, subsequent segment
Function Manual, 09/2019, A5E38120767B